Detailed Information

Cited 0 time in webofscience Cited 6 time in scopus
Metadata Downloads

Cholangiocarcinoma-An Automated Preliminary Detection System Using MLP

Full metadata record
DC Field Value Language
dc.contributor.authorLogeswaran, Rajasvaran-
dc.date.available2018-05-10T15:15:24Z-
dc.date.created2018-04-17-
dc.date.issued2009-12-
dc.identifier.issn0148-5598-
dc.identifier.urihttp://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/15732-
dc.description.abstractCholangiocarcinoma, cancer of the bile ducts, is often diagnosed via magnetic resonance cholangiopancreatography (MRCP). Due to low resolution, noise and difficulty is actually seeing the tumor in the images, especially by examining only a single image, there has been very little development of automated systems for cholangiocarcinoma diagnosis. This paper presents a computer-aided diagnosis (CAD) system for the automated preliminary detection of the tumor using a single MRCP image. The multi-stage system employs algorithms and techniques that correspond to the radiological diagnosis characteristics employed by doctors. A popular artificial neural network, the multi-layer perceptron (MLP), is used for decision making to differentiate images with cholangiocarcinoma from those without. The test results achieved was 94% when differentiating only healthy and tumor images, and 88% in a robust multi-disease test where the system had to identify the tumor images from a large set of images containing common biliary diseases.-
dc.publisherSPRINGER-
dc.relation.isPartOfJOURNAL OF MEDICAL SYSTEMS-
dc.subjectARTIFICIAL NEURAL-NETWORKS-
dc.subjectMRCP IMAGES-
dc.subjectCLASSIFICATION-
dc.subjectDIAGNOSIS-
dc.titleCholangiocarcinoma-An Automated Preliminary Detection System Using MLP-
dc.typeArticle-
dc.identifier.doi10.1007/s10916-008-9203-3-
dc.type.rimsART-
dc.identifier.bibliographicCitationJOURNAL OF MEDICAL SYSTEMS, v.33, no.6, pp.413 - 421-
dc.description.journalClass1-
dc.identifier.wosid000270881900002-
dc.identifier.scopusid2-s2.0-70350236556-
dc.citation.endPage421-
dc.citation.number6-
dc.citation.startPage413-
dc.citation.titleJOURNAL OF MEDICAL SYSTEMS-
dc.citation.volume33-
dc.contributor.affiliatedAuthorLogeswaran, Rajasvaran-
dc.type.docTypeArticle-
dc.subject.keywordAuthorMagnetic resonance cholangiopancreatography (MRCP)-
dc.subject.keywordAuthorCancer-
dc.subject.keywordAuthorTumor-
dc.subject.keywordAuthorBile ducts-
dc.subject.keywordAuthorComputer-aided diagnosis-
dc.subject.keywordPlusARTIFICIAL NEURAL-NETWORKS-
dc.subject.keywordPlusMRCP IMAGES-
dc.subject.keywordPlusCLASSIFICATION-
dc.subject.keywordPlusDIAGNOSIS-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Information Technology > Global School of Media > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE