Development of 7-Year-Old Korean Child Model for Computational Dosimetry
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Ae-Kyoung | - |
dc.contributor.author | Byun, Jin-Kyu | - |
dc.contributor.author | Park, Jin Seo | - |
dc.contributor.author | Choi, Hyung-Do | - |
dc.contributor.author | Yun, Jaehoon | - |
dc.date.available | 2018-05-10T15:20:39Z | - |
dc.date.created | 2018-04-17 | - |
dc.date.issued | 2009-04 | - |
dc.identifier.issn | 1225-6463 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/15857 | - |
dc.description.abstract | A whole-body voxel model of a 7-year-old male volunteer was developed from 384 axial magnetic resonance images (MRIs). The MRIs were acquired with intervals of 3 mm for the entire body in a body coil. In order to reduce the MRI acquisition time for the child the repetition and echo times under T1 weighted image were chosen to be 566 ins and 8 ins, respectively. The MRIs were classified according to 30 types of tissues with known electrical parameters. The developed voxel model was adjusted to the physical average of 7-year-old Korean boys. The boas weight of the adjusted model, calculated with the moss tissue densities, is within a 6% difference from the 50th percentile weight. | - |
dc.publisher | ELECTRONICS TELECOMMUNICATIONS RESEARCH INST | - |
dc.relation.isPartOf | ETRI JOURNAL | - |
dc.title | Development of 7-Year-Old Korean Child Model for Computational Dosimetry | - |
dc.type | Article | - |
dc.identifier.doi | 10.4218/etrij.09.0208.0342 | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | ETRI JOURNAL, v.31, no.2, pp.237 - 239 | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000265288300018 | - |
dc.identifier.scopusid | 2-s2.0-65249188455 | - |
dc.citation.endPage | 239 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 237 | - |
dc.citation.title | ETRI JOURNAL | - |
dc.citation.volume | 31 | - |
dc.contributor.affiliatedAuthor | Byun, Jin-Kyu | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | Whole-body child voxel model | - |
dc.subject.keywordAuthor | magnetic resonance image | - |
dc.subject.keywordAuthor | electromagnetic exposure | - |
dc.subject.keywordAuthor | dosimetry | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Soongsil University Library 369 Sangdo-Ro, Dongjak-Gu, Seoul, Korea (06978)02-820-0733
COPYRIGHT ⓒ SOONGSIL UNIVERSITY, ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.