배전변전소에 대용량변압기로 교체 적용시 보호협조를 위한 초전도 전류제한기의 임피던스 분석
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김진석 | - |
dc.contributor.author | 김명후 | - |
dc.contributor.author | 류일경 | - |
dc.contributor.author | 임성훈 | - |
dc.contributor.author | 김재철 | - |
dc.contributor.author | 안재민 | - |
dc.contributor.author | 문종필 | - |
dc.date.available | 2018-05-10T15:46:54Z | - |
dc.date.created | 2018-04-17 | - |
dc.date.issued | 2009 | - |
dc.identifier.issn | 1229-2443 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/16549 | - |
dc.description.abstract | The introduction of the large transformer due to the large power demand has increased the fault current in power distribution system. The increased fault current can exceed the cut-off ratings of the circuit breaker. As the methods to solve this problem, the superconducting fault current limiter(SFCL) has been notified. However, the limited fault current by SFCL affects the operational characteristics of the protective device such as overcurrent relay. Therefore, the selection of the proper impedance for the SFCL is required to keep overcurrent relay's protective coordination with the SFCL when a large transformer is introduced into the distribution system. In this paper, the SFCL's impedance for protective coordination was investigates in that a large transformer is introduced. | - |
dc.publisher | 대한전기학회 | - |
dc.relation.isPartOf | 전기학회논문지ABCD | - |
dc.subject | Superconducting Fault Current Limiter | - |
dc.subject | Power System | - |
dc.subject | Large Transformer | - |
dc.subject | Protective Coordination | - |
dc.subject | Superconducting Fault Current Limiter | - |
dc.subject | Power System | - |
dc.subject | Large Transformer | - |
dc.subject | Protective Coordination | - |
dc.title | 배전변전소에 대용량변압기로 교체 적용시 보호협조를 위한 초전도 전류제한기의 임피던스 분석 | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | 전기학회논문지ABCD, v.58, no.8, pp.1479 - 1484 | - |
dc.identifier.kciid | ART001366150 | - |
dc.description.journalClass | 2 | - |
dc.citation.endPage | 1484 | - |
dc.citation.number | 8 | - |
dc.citation.startPage | 1479 | - |
dc.citation.title | 전기학회논문지ABCD | - |
dc.citation.volume | 58 | - |
dc.contributor.affiliatedAuthor | 김진석 | - |
dc.contributor.affiliatedAuthor | 임성훈 | - |
dc.contributor.affiliatedAuthor | 김재철 | - |
dc.contributor.affiliatedAuthor | 문종필 | - |
dc.subject.keywordAuthor | Superconducting Fault Current Limiter | - |
dc.subject.keywordAuthor | Power System | - |
dc.subject.keywordAuthor | Large Transformer | - |
dc.subject.keywordAuthor | Protective Coordination | - |
dc.subject.keywordAuthor | Superconducting Fault Current Limiter | - |
dc.subject.keywordAuthor | Power System | - |
dc.subject.keywordAuthor | Large Transformer | - |
dc.subject.keywordAuthor | Protective Coordination | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Soongsil University Library 369 Sangdo-Ro, Dongjak-Gu, Seoul, Korea (06978)02-820-0733
COPYRIGHT ⓒ SOONGSIL UNIVERSITY, ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.