Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

바닥공조시스템에서 복사온도가 열적 쾌적성에 미치는 영향

Full metadata record
DC Field Value Language
dc.contributor.author정재동-
dc.contributor.author홍희기-
dc.contributor.author유호선-
dc.date.available2018-05-10T16:09:09Z-
dc.date.created2018-04-17-
dc.date.issued2008-
dc.identifier.issn1229-6422-
dc.identifier.urihttp://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/17088-
dc.description.abstractDespite the fact that UFAD(Under Floor Air Distribution) systems have many benefits and are being applied in the field in increasing numbers, there is a strong need for an improved fundamental understanding of several key performance features of these systems. This study numerically investigates the effect of supplied air temperature and supplied flow rate on the performance of UFAD, especially focused on thermal comfort. Also this study has compared UFAD with conventional overhead air distribution system. In contrast to the well- mixed room air conditions of the conventional overheat system, UFAD system produces an overall floor-to-ceiling airflow pattern that takes advantage of the natural buoyancy produced by heat sources in the occupied zone and more efficiently removes heat loads and contaminants from the space. Thermal comfort parameters were evaluated by CFD approach and then PMV was computed to detect the occupants’ thermal sensation. Results show that radiative mean temperature plays crucial role on the evaluating PMV. Until now, the radiative temperature has been the missing link between CFD and thermal comfort, but the present study paves the way for overcoming this weakness.-
dc.publisher대한설비공학회-
dc.relation.isPartOf설비공학 논문집-
dc.subjectUFAD(바닥공조시스템)-
dc.subjectRadiative Mean Temperature(평균복사온도)-
dc.subjectThermal Comfort(열적쾌적성)-
dc.subjectStratification(성층)-
dc.title바닥공조시스템에서 복사온도가 열적 쾌적성에 미치는 영향-
dc.typeArticle-
dc.type.rimsART-
dc.identifier.bibliographicCitation설비공학 논문집, v.20, no.11, pp.711 - 717-
dc.identifier.kciidART001291331-
dc.description.journalClass2-
dc.citation.endPage717-
dc.citation.number11-
dc.citation.startPage711-
dc.citation.title설비공학 논문집-
dc.citation.volume20-
dc.contributor.affiliatedAuthor유호선-
dc.subject.keywordAuthorUFAD(바닥공조시스템)-
dc.subject.keywordAuthorRadiative Mean Temperature(평균복사온도)-
dc.subject.keywordAuthorThermal Comfort(열적쾌적성)-
dc.subject.keywordAuthorStratification(성층)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Ho seon photo

Yoo, Ho seon
College of Engineering (School of Mechanical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE