정수처리시설에서 막공정 도입시 침전공정생략 가능성에 관한 연구A Study on possibility of sedimentation basin omission after installed membrane system in drinking water treatment
- Other Titles
- A Study on possibility of sedimentation basin omission after installed membrane system in drinking water treatment
- Authors
- 김형선; 김성진; 홍성호; 조춘구; 이길숙
- Issue Date
- Jun-2006
- Publisher
- 대한상하수도학회
- Keywords
- PAC; MF; UF; DOC; sedimentation basin; coagulant; 분말활성탄; 정밀여과; 한외여과; 용존유기물질; 침전조; 응집제*Corresponding author Tel. : +81-2-820-0617; FAX:+81-2-812-5378; E-mail: ckzhoh@ssu.ac.kr; PAC; MF; UF; DOC; sedimentation basin; coagulant
- Citation
- 상하수도학회지, v.20, no.3, pp.403 - 410
- Journal Title
- 상하수도학회지
- Volume
- 20
- Number
- 3
- Start Page
- 403
- End Page
- 410
- URI
- http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/18842
- ISSN
- 1225-7672
- Abstract
- The objective of this study was to evaluate the possibility of sedimentation basin omission when installed hybrid membrane filtration process in the field plant with the capacity of 500m3/day for 11 months in the "G". water purification plant in Seoul. In order to evaluate the possibility of the sedimentation basin omission, we measured the change of DOC by coagulant dosage. Dosage of PAC(power activated carbon) 4mg/L and coagulant(Al2O3 10%) 1.67mg/L were compatible to meet the water quality. Also according to the experiment without settlement process, optimization G values were determined to be 300/s, 64/s, and 32/s at the mixing tank, the first flocculator and the second flocculator, respectively. The test was performed under the conditions PAC-coagulation-no settlement-MF. As a result, a dosage of 4.0mg/L as PAC and 0.86 to 1.22mg/L as Al2O3(10%) in the condition of flux of 62.5LMH were determined to keep TMP value less than 1.0kgf/cm2.
- Files in This Item
-
Go to Link
- Appears in
Collections - College of Engineering > Department of Chemical Engineering > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.