강제환기가 적용된 시험공간에서 냉난방부하의 시뮬레이션 및 실증실험
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김동혁 | - |
dc.contributor.author | 홍희기 | - |
dc.contributor.author | 유호선 | - |
dc.contributor.author | 김욱중 | - |
dc.date.available | 2018-05-10T17:25:44Z | - |
dc.date.created | 2018-04-17 | - |
dc.date.issued | 2006-12 | - |
dc.identifier.issn | 1229-6422 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/19036 | - |
dc.description.abstract | Building energy consumption according to the ventilation has been considered to be an important subject. The purpose of this study is to investigate the cooling and heating loads in a test space with a forced ventilating system. In the test space, on/off controlled air-conditioning and forced ventilating facility were operated between 8:30 to 21:00 during 4 days and some important data like temperatures and energy consumption were measured to obtain actual thermal loads. The simulation was carried out in a mode of temperature level control using a TRNSYS 15.3 with a precisely measured air change amount and performance data of air-conditioner. Heating load and cooling load including sensible and latent were compared between by experiment and by simulation. Both of thermal loads associated with ventilation show a close agreement within an engineering tolerance. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 대한설비공학회 | - |
dc.relation.isPartOf | 설비공학 논문집 | - |
dc.subject | Cooling load(냉방부하) | - |
dc.subject | Heating load(난방부하) | - |
dc.subject | TRNSYS | - |
dc.subject | Dynamic load calculation(동적열부하계산) | - |
dc.subject | Forced ventilation(강제환기) | - |
dc.subject | Performance data(성능데이터) | - |
dc.subject | Building energy simulation(건물에너지 시뮬레이션) | - |
dc.title | 강제환기가 적용된 시험공간에서 냉난방부하의 시뮬레이션 및 실증실험 | - |
dc.title.alternative | Simulation and Verification Experiment of Cooling and Heating Loadfor a Test Space with Forced Ventilation | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | 설비공학 논문집, v.18, no.12, pp.947 - 954 | - |
dc.identifier.kciid | ART001101526 | - |
dc.description.journalClass | 2 | - |
dc.citation.endPage | 954 | - |
dc.citation.number | 12 | - |
dc.citation.startPage | 947 | - |
dc.citation.title | 설비공학 논문집 | - |
dc.citation.volume | 18 | - |
dc.contributor.affiliatedAuthor | 유호선 | - |
dc.identifier.url | https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001101526 | - |
dc.description.isOpenAccess | N | - |
dc.subject.keywordAuthor | Cooling load(냉방부하) | - |
dc.subject.keywordAuthor | Heating load(난방부하) | - |
dc.subject.keywordAuthor | TRNSYS | - |
dc.subject.keywordAuthor | Dynamic load calculation(동적열부하계산) | - |
dc.subject.keywordAuthor | Forced ventilation(강제환기) | - |
dc.subject.keywordAuthor | Performance data(성능데이터) | - |
dc.subject.keywordAuthor | Building energy simulation(건물에너지 시뮬레이션) | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Soongsil University Library 369 Sangdo-Ro, Dongjak-Gu, Seoul, Korea (06978)02-820-0733
COPYRIGHT ⓒ SOONGSIL UNIVERSITY, ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.