다수의 냉각탑이 설치된 옥상에서 냉각탑별 재유입률 예측
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이태구 | - |
dc.contributor.author | 문선애 | - |
dc.contributor.author | 유호선 | - |
dc.contributor.author | 이재헌 | - |
dc.date.available | 2018-05-10T17:26:28Z | - |
dc.date.created | 2018-04-17 | - |
dc.date.issued | 2006-11 | - |
dc.identifier.issn | 1229-6422 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/19055 | - |
dc.description.abstract | In this paper, reentering ratio and cooling capacity of individual cooling towers arrayed on a building roof were studied by a numerical method. The number of 16 cooling towers were divided into 4 banks. It was considered the summer prevailing wind characteristics as west wind and south wind of 5m/s. It was also considered the roofwall types as the curtainwall and the louverwall that had the outdoor air intake louver in the curtainwall. In this case, the louver was suggested as the solution that could prevent reentering phenomenon due to recirculation and interference of the discharge air. In the case of the curtainwall, the averaged reentering ratio are predicted 13.3% and 24.4% for the west and south wind of 5 m/s, respectively. In the case of the louverwall, the averaged reentering ratio are predicted 2.5% and 9.7% for the west and south wind of 5m/s, respectively. Therefore, the louverwall is a appropriate solution for reducing the reentering phenomenon. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 대한설비공학회 | - |
dc.relation.isPartOf | 설비공학 논문집 | - |
dc.subject | Cooling tower(냉각탑) | - |
dc.subject | Recirculation(재순환) | - |
dc.subject | Interference(간섭) | - |
dc.subject | Reentering rate(재유입률) | - |
dc.title | 다수의 냉각탑이 설치된 옥상에서 냉각탑별 재유입률 예측 | - |
dc.title.alternative | Prediction of Reentering Ratio of Individual Cooling Towers Scatteredon a Building Roof | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | 설비공학 논문집, v.18, no.11, pp.923 - 932 | - |
dc.identifier.kciid | ART001026919 | - |
dc.description.journalClass | 2 | - |
dc.citation.endPage | 932 | - |
dc.citation.number | 11 | - |
dc.citation.startPage | 923 | - |
dc.citation.title | 설비공학 논문집 | - |
dc.citation.volume | 18 | - |
dc.contributor.affiliatedAuthor | 유호선 | - |
dc.identifier.url | https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001026919 | - |
dc.description.isOpenAccess | N | - |
dc.subject.keywordAuthor | Cooling tower(냉각탑) | - |
dc.subject.keywordAuthor | Recirculation(재순환) | - |
dc.subject.keywordAuthor | Interference(간섭) | - |
dc.subject.keywordAuthor | Reentering rate(재유입률) | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Soongsil University Library 369 Sangdo-Ro, Dongjak-Gu, Seoul, Korea (06978)02-820-0733
COPYRIGHT ⓒ SOONGSIL UNIVERSITY, ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.