압전필름을 센서로 사용한 접촉식 계수장치 개발Development of a Contact-Type Counting Device Using a Piezoelectric Film as a Sensor
- Other Titles
- Development of a Contact-Type Counting Device Using a Piezoelectric Film as a Sensor
- Authors
- 유완동; 김진오; 박광훈
- Issue Date
- Feb-2005
- Publisher
- 한국소음진동공학회
- Keywords
- 압전필름; 센서; 계수장치; 굽힘진동; Piezoelectric Film; Sensor; Counting Device; Bending Vibration
- Citation
- 한국소음진동공학회논문집, v.15, no.2, pp.239 - 247
- Journal Title
- 한국소음진동공학회논문집
- Volume
- 15
- Number
- 2
- Start Page
- 239
- End Page
- 247
- URI
- http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/19695
- ISSN
- 1598-2785
- Abstract
- This paper deals with the development of a contact-type counting device using a piezoelectric polymer film as a sensor. The piezoelectric and vibration characteristics of the film under a bending vibration were investigated theoretically and experimentally. A counting device, which includes filters, an amplifier, an analog-digital converter, and a display, was designed and fabricated. The performance of the piezoelectric polymer sensor was evaluated in the sense of the responses to contact force, contact frequency, and contact speed. The life and the temperature effect were also investigated for the piezoelectric film sensor.
- Files in This Item
-
Go to Link
- Appears in
Collections - College of Engineering > ETC > 1. Journal Articles
![qrcode](https://api.qrserver.com/v1/create-qr-code/?size=55x55&data=https://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/19695)