dc.description.abstractBased on the T-method, a new scheme for predicting air flow rate distribution in a bathroom exhaust system is developed. Introduction of individual duct route enables us to disintegrate a complicated multi-fan ductwork into a set of simultaneous single-fan subsystems. The scheme is validated via the analysis of a well-posed test problem, showing physical consistency. In order to demonstrate the utility and capability of our method, the bathroom ventilation system in a 20-story residential building is selected as an example. Under the typical design condition, the air flow rate of each exhaust fan at the balancing point is successfully predicted, and such information can lead to an engineering estimation for the overall system performance. While some deficiencies in ventilation are found at bathrooms at lower floors with 6 mmAq-rated exhaust fans, they disappear over the whole building by using fans of enhanced static pressures, 7 and 8 mmAq. Finally the present scheme seems to be useful for practical design of multi-branched, multi-fan ventilation systems.-
dc.language한국어-
dc.language.isoko-
dc.publisher대한설비공학회-
dc.relation.isPartOf설비공학 논문집-
dc.subjectExhaust system(배기시스템)-
dc.subjectFlow rate distribution(유량분배)-
dc.subjectVentilation(환기)-
dc.subjectDuct(덕트)-
dc.subjectT-method-
dc.subjectbathroom(욕실)-
dc.subjectExhaust system(배기시스템)-
dc.subjectFlow rate distribution(유량분배)-
dc.subjectVentilation(환기)-
dc.subjectDuct(덕트)-
dc.subjectT-method-
dc.subjectbathroom(욕실)-
dc.titleT-method를 이용한 고층 아파트 욕실 배기시스템의 층별 유량분배 해석-
dc.title.alternativeAnalysis of Air Flow Rate Distribution for the Bathroom Exhaust System in High-rise Buildings Using T-method-
dc.typeArticle-
dc.type.rimsART-
dc.identifier.bibliographicCitation설비공학 논문집, v.16, no.3, pp.265 - 272-
dc.identifier.kciidART000928964-
dc.description.journalClass2-
dc.citation.endPage272-
dc.citation.number3-
dc.citation.startPage265-
dc.citation.title설비공학 논문집-
dc.citation.volume16-
dc.contributor.affiliatedAuthor유호선-
dc.identifier.urlhttps://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART000928964-
dc.description.isOpenAccessN-
dc.subject.keywordAuthorExhaust system(배기시스템)-
dc.subject.keywordAuthorFlow rate distribution(유량분배)-
dc.subject.keywordAuthorVentilation(환기)-
dc.subject.keywordAuthorDuct(덕트)-
dc.subject.keywordAuthorT-method-
dc.subject.keywordAuthorbathroom(욕실)-
dc.subject.keywordAuthorExhaust system(배기시스템)-
dc.subject.keywordAuthorFlow rate distribution(유량분배)-
dc.subject.keywordAuthorVentilation(환기)-
dc.subject.keywordAuthorDuct(덕트)-
dc.subject.keywordAuthorT-method-
dc.subject.keywordAuthorbathroom(욕실)-
dc.description.journalRegisteredClasskci-
Files in This Item
Go to Link
Appears in
Collections
College of Engineering > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Ho seon photo

Yoo, Ho seon
College of Engineering (School of Mechanical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE