Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

外氣에 면한 超高層 아파트 발코니 천정 내부결로 예측Forecast on Internal Condensation at Balcony Ceiling of Super-high Apartment Building Faced with Open Air

Other Titles
Forecast on Internal Condensation at Balcony Ceiling of Super-high Apartment Building Faced with Open Air
Authors
최윤기안재봉
Issue Date
Dec-2003
Publisher
한국건설관리학회
Keywords
열교; 내부결로; 온도예측; 습기압분포; 상대습도; Thermal bridge; Internal condensation; Temperature forecast; Humidity pressure range; Relative humidity―――――――――――――――――――――――――――――――――――――――――――――――――; Thermal bridge; Internal condensation; Temperature forecast; Humidity pressure range; Relative humidity―――――――――――――――――――――――――――――――――――――――――――――――――
Citation
한국건설관리학회 논문집, v.4, no.4, pp.155 - 163
Journal Title
한국건설관리학회 논문집
Volume
4
Number
4
Start Page
155
End Page
163
URI
http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/20750
ISSN
2005-6095
Abstract
최근 들어 주거공간의 기능만족과 효율성 확보를 위해 외기측에 면한 발코니 부위를 확장하는 사례가 늘어나고 있으며 특히, 최상층에 위치한 확장형 주거공간의 경우 외벽에 설치된 AL Curtain wall 상부 외벽복합 Panel 이 완전 기밀하지 않음으로 인해 천정 상부측으로 낮은 외기온의 이동에 의한 실온과의 온도차에 의해 내부결로의 발생 가능성을 전혀 배제할 수는 없는 상황이다. 본 연구는 외기에 면한 초고층 아파트 최상층부의 발코니 천장내부에 있는 H-Beam(내화피복+단열재 구성)과 Parapet부위 내부결로 발생가능성에 대한 예측을 해 봄으로써 해당 공간거주자의 쾌적한 환경 만족 및 불안을 해소 하는데 그 목적이 있다. 외주부를 구성하고 있는 Curtain wall, Stone panel 또는 슬래브 바닥하부 등의 열적 취약공간에 대해 2차원 정상상태(온도평형) 열전도해석 Program을 이용, 온도예측과 온도분포해석을 통해 해당부위의 수증기압 분포에 따른 내부결로 예측을 실시하였다.
Files in This Item
Go to Link
Appears in
Collections
College of Engineering > School of Architecture > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Yoon Ki photo

Choi, Yoon Ki
College of Engineering (School of Architecture)
Read more

Altmetrics

Total Views & Downloads

BROWSE