무선전력전송 시스템의 자기장 인체노출 평가를 위한 결합계수 분석
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 심재훈 | - |
dc.contributor.author | 정규진 | - |
dc.contributor.author | 변진규 | - |
dc.date.available | 2019-03-13T01:51:25Z | - |
dc.date.created | 2018-10-03 | - |
dc.date.issued | 2018-03 | - |
dc.identifier.issn | 1229-4691 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/31834 | - |
dc.description.abstract | In this paper, coupling factors are calculated for assessment of human exposure to magnetic field from a wireless power transfer system. Two different types of coupling factors are calculated using electromagnetic field simulations according to the definitions in IEC 62226-2-1 and IEC 62311 standards, respectively. The resonant wireless power transfer system is designed with 2MHz operating frequency. For equivalent human model, simplified homogeneous human model in IEC 62311 standard is used. The variation of the coupling factor is analyzed according to the horizontal distance and vertical location of the transmitter with respect to the human body, and the safety assessment considerations for the wireless power devices are discussed based on the results. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 한국조명.전기설비학회 | - |
dc.relation.isPartOf | 조명.전기설비학회논문지 | - |
dc.subject | Coupling Factor | - |
dc.subject | Human Body Exposure | - |
dc.subject | Magnetic Field | - |
dc.subject | Wireless Power Transfer | - |
dc.title | 무선전력전송 시스템의 자기장 인체노출 평가를 위한 결합계수 분석 | - |
dc.type | Article | - |
dc.identifier.doi | 10.5207/JIEIE.2018.32.3.059 | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | 조명.전기설비학회논문지, v.32, no.3, pp.59 - 65 | - |
dc.identifier.kciid | ART002327953 | - |
dc.description.journalClass | 2 | - |
dc.citation.endPage | 65 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 59 | - |
dc.citation.title | 조명.전기설비학회논문지 | - |
dc.citation.volume | 32 | - |
dc.contributor.affiliatedAuthor | 변진규 | - |
dc.identifier.url | http://www.dbpia.co.kr/Article/NODE07406996 | - |
dc.description.isOpenAccess | N | - |
dc.subject.keywordAuthor | Coupling Factor | - |
dc.subject.keywordAuthor | Human Body Exposure | - |
dc.subject.keywordAuthor | Magnetic Field | - |
dc.subject.keywordAuthor | Wireless Power Transfer | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Soongsil University Library 369 Sangdo-Ro, Dongjak-Gu, Seoul, Korea (06978)02-820-0733
COPYRIGHT ⓒ SOONGSIL UNIVERSITY, ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.