Detailed Information

Cited 13 time in webofscience Cited 15 time in scopus
Metadata Downloads

Hydrophilic and positively charged polyethylenimine-functionalized mesoporous magnetic clusters for highly efficient removal of Pb(II) and Cr(VI) from wastewater

Authors
Lee, Min YoungLee, Ji HwanChung, Jae WooKwak, Seung-Yeop
Issue Date
Jan-2018
Publisher
ACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD
Keywords
Pb(II); Cr(VI); Branched polyethylenimine; Positively charged branched; polyethylenimine; Mesoporous magnetic clusters
Citation
JOURNAL OF ENVIRONMENTAL MANAGEMENT, v.206, pp.740 - 748
Journal Title
JOURNAL OF ENVIRONMENTAL MANAGEMENT
Volume
206
Start Page
740
End Page
748
URI
http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/32109
DOI
10.1016/j.jenvman.2017.10.051
ISSN
0301-4797
Abstract
We develop mesoporous magnetic clusters (MMCs) functionalized with hydrophilic branched polyethylenimine (b-PEI), later called b-MG, and MMCs functionalized with positively charged b-PEI (p-MG). These materials efficiently remove Pb(II) and Cr(VI) from wastewater. Fourier-transform infrared spectroscopy, X-ray photoelectron spectroscopy, thermogravimetric analysis, and nitrogen adsorption desorption analysis results clearly indicate that hydrophilic b-PEI and positively charged b-PEI are successfully attached to the MMC surfaces. Wide-angle X-ray diffraction, high-resolution transmission electron microscopy, and field-emission scanning electron microscopy analyses confirm that the crystal structures and morphologies of the MMCs are maintained well even when wet chemical modification processes are used to introduce hydrophilic b-PEI and positively charged b-PEI to the MMC surfaces. Langmuir and Sips isotherm models are applied to describe Pb(II) adsorption behavior of the b-MG and Cr(VI) adsorption behavior of the p-MG. The isotherm models indicate that the maximum adsorption capacities of b-MG and p-MG, respectively, are 216.3 and 334.1 mg g(-1), respectively. These are higher than have previously been found for other adsorbents. In reusability tests, using magnetic separation and controlling the pH, the Pb(II) recovery efficiency of the b-MG is 95.6% and the Cr(VI) recovery efficiency of the p-MG is 68.0% even after the third cycle. (C) 2017 Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Jae Woo photo

Chung, Jae Woo
College of Engineering (Department of Materials Science and Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE