Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Application of synthetic sinogram based low-dose CT simulation and fold-preserving electronic cleansing technique for CT colonography

Full metadata record
DC Field Value Language
dc.contributor.authorKim, C.-W.-
dc.contributor.authorKim, J.-H.-
dc.contributor.authorLee, H.-
dc.contributor.authorLee, J.-
dc.contributor.authorKim, S.-H.-
dc.contributor.authorYang, Z.-
dc.contributor.authorShin, Y.-G.-
dc.date.available2019-04-10T10:23:49Z-
dc.date.created2018-04-17-
dc.date.issued2013-
dc.identifier.isbn9783642410826-
dc.identifier.issn0302-9743-
dc.identifier.urihttp://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/32888-
dc.description.abstractThis study evaluates the performance of the electronic cleansing technique in ultra-low-dose CT colonography, and explores the potential limit of the dose level which hampers the proper working of the electronic cleansing. We applied a synthetic sinogram-based low-dose CT simulation technique to the DICOM images CT colonography studies to generate a set of ultra-low-dose CT colonography dataset ranging 20, 10, 5, and 1 mAs conditions. A fold-preserving electronic cleansing technique was applied to those ultra-low-dose CT colonography (CTC) dataset and the tagging cleansing performance was evaluated for each dose-level. © 2013 Springer-Verlag.-
dc.relation.isPartOfLecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)-
dc.titleApplication of synthetic sinogram based low-dose CT simulation and fold-preserving electronic cleansing technique for CT colonography-
dc.typeConference-
dc.identifier.doi10.1007/978-3-642-41083-3_11-
dc.type.rimsCONF-
dc.identifier.bibliographicCitation5th International Workshop on Abdominal Imaging: Computation and Clinical Applications, Held in Conjunction with 16th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2013, v.8198 LNCS, pp.89 - 98-
dc.description.journalClass2-
dc.identifier.scopusid2-s2.0-84886562477-
dc.citation.conferenceDate2013-09-22-
dc.citation.conferencePlaceNagoya-
dc.citation.endPage98-
dc.citation.startPage89-
dc.citation.title5th International Workshop on Abdominal Imaging: Computation and Clinical Applications, Held in Conjunction with 16th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2013-
dc.citation.volume8198 LNCS-
dc.contributor.affiliatedAuthorLee, J.-
dc.type.docTypeConference Paper-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Information Technology > School of Computer Science and Engineering > 2. Conference Papers

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jeong Jin photo

Lee, Jeong Jin
College of Information Technology (School of Computer Science and Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE