Protective Coordination of the OCR with the Voltage Component in a Closed-Loop Power Distribution System with the FCL

Authors
Lim, Seung-taekLim, Sung-hun
Issue Date
Nov-2020
Publisher
Korean Institute of Electrical Engineers
Keywords
Overcurrent relay (OCR); Power system protection; Protection coordination; Superconducting fault current limiter (SFCL)
Citation
Journal of Electrical Engineering and Technology, v.15, no.6, pp.2451 - 2457
Journal Title
Journal of Electrical Engineering and Technology
Volume
15
Number
6
Start Page
2451
End Page
2457
URI
http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/38588
DOI
10.1007/s42835-020-00522-6
ISSN
1975-0102
Abstract
Recently, the requirement of the electrical energy from the renewable source has been growing in the South Korea since government’s energy plan to generate the electrical power of 20% as renewable source. In addition, these renewable power plants have been constructed on not only the existing power plant’s side but also customer’s side. These changes in power distribution system cause the fault current to increase higher and to reverse the direction of the fault current. Variable countermeasures to reduce the fault current have been studied and the introduction of the superconducting fault current limiter (SFCL) in the power distribution system, one of them, has been actively reported. However, the installation of the SFCL can affect the power system protection because of the fault current’s decrease or increase, which depends on the construction of the power distribution system. Especially, the application of the SFCL in a closed-loop power distribution system can cause the delayed trip operation or the fast trip operation of the over-current relay (OCR), one of the representative protective devices widely used in a power distribution system. This change can influence on the existed protective coordination. In this paper, the OCR with voltage component, one of the methods to suppress its trip operation’s change in a power distribution system with a closed loop construction due to the application of the SFCL, was suggested and the protection coordination between the OCRs in a power distribution system with a closed loop was analyzed. It was confirmed that a simple using voltage component in the OCR could cause the trip variation of the reverse direction OCR in loop power system and it can be improved by matching the relaying voltage components. © 2020, The Korean Institute of Electrical Engineers.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Sung Hun photo

Lim, Sung Hun
College of Engineering (School of Electrical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE