Detailed Information

Cited 1 time in webofscience Cited 3 time in scopus
Metadata Downloads

Punching-shear behavior of slabs with bar truss shear reinforcement on rectangular columns

Full metadata record
DC Field Value Language
dc.contributor.authorEom, Tae-Sung-
dc.contributor.authorSong, Jeong-Won-
dc.contributor.authorSong, Jin-Kyu-
dc.contributor.authorKang, Gi-Sung-
dc.contributor.authorYoon, Jang-Keun-
dc.contributor.authorKang, Su-Min-
dc.date.available2020-09-14T09:05:58Z-
dc.date.created2019-11-19-
dc.date.issued2017-03-
dc.identifier.issn0141-0296-
dc.identifier.urihttp://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/39319-
dc.description.abstractIn this study, punching-shear tests were performed to investigate the behavior of slabs supported by rectangular columns with capital. The slabs were subjected to an uneven shear transfer in two orthogonal directions by using the rectangular columns and different span lengths. Column capitals were used at the slab-column joints and preassembled bar trusses were placed at the periphery of the column capital to enhance the punching-shear capacity. Furthermore, the corners of the rectangular column and column capital were rounded to alleviate the shear stress concentration at the corners of the critical perimeter for shear. The test results show that the punching-shear strength of the slabs were significantly enhanced by the bar trusses. The shear resistance of the bar trusses was mostly contributed by the diagonal bars undergoing significant strains. On the basis of the results, the effects of the uneven shear transfer and bar truss arrangement on the slab shear behavior were investigated. In addition, the punching-shear strengths predicted by ACI 318-14, Eurocode 2, and KCI 2012 were compared with the test strengths. (C) 2016 Elsevier Ltd. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCI LTD-
dc.relation.isPartOfENGINEERING STRUCTURES-
dc.titlePunching-shear behavior of slabs with bar truss shear reinforcement on rectangular columns-
dc.typeArticle-
dc.identifier.doi10.1016/j.engstruct.2016.12.048-
dc.type.rimsART-
dc.identifier.bibliographicCitationENGINEERING STRUCTURES, v.134, pp.390 - 399-
dc.description.journalClass1-
dc.identifier.wosid000394062400028-
dc.identifier.scopusid2-s2.0-85008388678-
dc.citation.endPage399-
dc.citation.startPage390-
dc.citation.titleENGINEERING STRUCTURES-
dc.citation.volume134-
dc.contributor.affiliatedAuthorKang, Su-Min-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.subject.keywordAuthorPunching shear-
dc.subject.keywordAuthorSlab-
dc.subject.keywordAuthorTruss shear reinforcement-
dc.subject.keywordAuthorRectangular column-
dc.subject.keywordAuthorShear test-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryEngineering, Civil-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Architecture > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Su min photo

Kang, Su min
College of Engineering (School of Architecture)
Read more

Altmetrics

Total Views & Downloads

BROWSE