Target Range Selection of FMCW Radar for Accurate Vital Information Extraction
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Choi, Ho-Ik | - |
dc.contributor.author | Song, Heemang | - |
dc.contributor.author | Shin, Hyun-Chool | - |
dc.date.available | 2021-02-26T06:40:13Z | - |
dc.date.created | 2021-02-26 | - |
dc.date.issued | 2021-01 | - |
dc.identifier.issn | 2169-3536 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/40286 | - |
dc.description.abstract | Frequency modulated continuous wave (FMCW) radar, which can detect the range and small displacement of a target, has been used for contactless vital information extraction. For accurate vital sign (respiration and heartbeat) measurement, a precise selection of the target range bin, where vital information exists, is important. In this paper, an effective method for selecting the range bin with accurate vital information is proposed. The proposed method is based on the newly introduced magnitude-phase coherency (MPC) index. The experimental results show that the vital information extracted by the proposed method is more accurate than those by conventional methods, indicating that the proposed range bin selection based on MPC is an effective method for extracting accurate respiration and heartbeat rates. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.relation.isPartOf | IEEE ACCESS | - |
dc.title | Target Range Selection of FMCW Radar for Accurate Vital Information Extraction | - |
dc.type | Article | - |
dc.identifier.doi | 10.1109/ACCESS.2020.3043013 | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | IEEE ACCESS, v.9, pp.1261 - 1270 | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000606568700001 | - |
dc.identifier.scopusid | 2-s2.0-85097951503 | - |
dc.citation.endPage | 1270 | - |
dc.citation.startPage | 1261 | - |
dc.citation.title | IEEE ACCESS | - |
dc.citation.volume | 9 | - |
dc.contributor.affiliatedAuthor | Shin, Hyun-Chool | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.subject.keywordAuthor | FMCW radar | - |
dc.subject.keywordAuthor | vital monitoring | - |
dc.subject.keywordAuthor | respiration | - |
dc.subject.keywordAuthor | heartbeat | - |
dc.subject.keywordAuthor | range bin selection | - |
dc.relation.journalResearchArea | Computer Science | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Telecommunications | - |
dc.relation.journalWebOfScienceCategory | Computer Science, Information Systems | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Telecommunications | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Soongsil University Library 369 Sangdo-Ro, Dongjak-Gu, Seoul, Korea (06978)02-820-0733
COPYRIGHT ⓒ SOONGSIL UNIVERSITY, ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.