Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Reliability of skeletal muscle area measurement on CT with different parameters: A phantom studyopen access

Authors
Kim, Dong-wookHa, JiyeonKo, YousunKim, Kyung-wonPark, TaeyongLee, JeongjinYou, Myung-wonYoon, KwonhaPark, Ji-yongKee, Young-jinKim, Hong-kyu
Issue Date
Apr-2021
Publisher
Korean Radiological Society
Keywords
Computed tomography; Muscle measurement; Phantom; Sarcopenia
Citation
Korean Journal of Radiology, v.22, no.4, pp.624 - 633
Journal Title
Korean Journal of Radiology
Volume
22
Number
4
Start Page
624
End Page
633
URI
http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/40900
DOI
10.3348/kjr.2020.0914
ISSN
1229-6929
Abstract
Objective: To evaluate the reliability of CT measurements of muscle quantity and quality using variable CT parameters. Materials and Methods: A phantom, simulating the L2-4 vertebral levels, was used for this study. CT images were repeatedly acquired with modulation of tube voltage, tube current, slice thickness, and the image reconstruction algorithm. Reference standard muscle compartments were obtained from the reference maps of the phantom. Cross-sectional area based on the Hounsfield unit (HU) thresholds of muscle and its components, and the mean density of the reference standard muscle compartment, were used to measure the muscle quantity and quality using different CT protocols. Signal-to-noise ratios (SNRs) were calculated in the images acquired with different settings. Results: The skeletal muscle area (threshold, -29 to 150 HU) was constant, regardless of the protocol, occupying at least 91.7% of the reference standard muscle compartment. Conversely, normal attenuation muscle area (30-150 HU) was not constant in the different protocols, varying between 59.7% and 81.7% of the reference standard muscle compartment. The mean density was lower than the target density stated by the manufacturer (45 HU) in all cases (range, 39.0-44.9 HU). The SNR decreased with low tube voltage, low tube current, and in sections with thin slices, whereas it increased when the iterative reconstruction algorithm was used. Conclusion: Measurement of muscle quantity using HU threshold was reliable, regardless of the CT protocol used. Conversely, the measurement of muscle quality using the mean density and narrow HU thresholds were inconsistent and inaccurate across different CT protocols. Therefore, further studies are warranted in future to determine the optimal CT protocols for reliable measurements of muscle quality. © 2021 The Korean Society of Radiology.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Information Technology > School of Computer Science and Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jeong Jin photo

Lee, Jeong Jin
College of Information Technology (School of Computer Science and Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE