Heating efficiency enhanced by combination of phase change materials and activated carbon for dry floor heating system

Full metadata record
DC Field Value Language
dc.contributor.authorJeong, Su-Gwang-
dc.contributor.authorHeo, Jeong Eun-
dc.contributor.authorChoi, Sang-Yeon-
dc.contributor.authorKim, Sumin-
dc.date.accessioned2023-10-11T05:40:03Z-
dc.date.available2023-10-11T05:40:03Z-
dc.date.created2023-10-11-
dc.date.issued2023-10-
dc.identifier.issn2352-152X-
dc.identifier.urihttps://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/44420-
dc.description.abstractPhase change materials (PCMs) have diverse applications in energy storage, buildings, cooling, and heat ex-changers. In this study, n-docosane and activated carbon (AC) were combined using the vacuum impregnation method to form an aggregate, which was then injected into a Poly vinyl chloride container and applied to a dry floor heating system. Thermal storage, gravimetric, conductivity, and specific heat analyses were performed to evaluate the thermal performance of n-docosane and AC-based heat-storage aggregate (D-HSA). The dynamic heat transfer performance and power consumption of the dry floor heating system after D-HSA application were then evaluated. Pure n-docosane and D-HSA showed latent heat capacities of 242.7 J/g and 235.1 J/g and 92.10 J/g and 92.66 J/g during heating and cooling. In terms of thermal durability, D-HSA was more stable than pure n-docosane. Thermal conductivity analysis revealed that D-HSA had a high thermal conductivity (approximately 597 %) in the liquid state. In the field-based dynamic heat transfer analysis experiment, the PCM dry floor heating system filled with D-HSA had the advantages of both dry and wet floor heating systems, namely, a fast surface temperature increase rate and the time-lag effect, respectively. Therefore, the PCM dry floor heating system can compensate for the disadvantages of the dry and wet floor heating systems and can be considered an efficient heating system in terms of energy savings.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER-
dc.relation.isPartOfJOURNAL OF ENERGY STORAGE-
dc.titleHeating efficiency enhanced by combination of phase change materials and activated carbon for dry floor heating system-
dc.typeArticle-
dc.identifier.doi10.1016/j.est.2023.108027-
dc.type.rimsART-
dc.identifier.bibliographicCitationJOURNAL OF ENERGY STORAGE, v.70-
dc.description.journalClass1-
dc.identifier.wosid001032427400001-
dc.identifier.scopusid2-s2.0-85162004454-
dc.citation.titleJOURNAL OF ENERGY STORAGE-
dc.citation.volume70-
dc.contributor.affiliatedAuthorJeong, Su-Gwang-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S2352152X2301424X?via%3Dihub-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.subject.keywordAuthorHeat-storage aggregate-
dc.subject.keywordAuthorN-docosane-
dc.subject.keywordAuthorActivated carbon-
dc.subject.keywordAuthorFloor heating system-
dc.subject.keywordAuthorDynamic heat transfer-
dc.subject.keywordPlusTHERMAL-ENERGY STORAGE-
dc.subject.keywordPlusPCM-
dc.subject.keywordPlusBUILDINGS-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusPARAFFIN-
dc.subject.keywordPlusWALLS-
dc.subject.keywordPlusMODEL-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
Go to Link
Appears in
Collections
College of Engineering > School of Architecture > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher JEONG, SU-GWANG photo

JEONG, SU-GWANG
College of Engineering (School of Architecture)
Read more

Altmetrics

Total Views & Downloads

BROWSE