Detailed Information

Cited 0 time in webofscience Cited 8 time in scopus
Metadata Downloads

Effect of Splenic Artery Embolization for Splenic Artery Steal Syndrome in Liver Transplant Recipients: Estimation at Computed Tomography Based on Changes in Caliber of Related Arteries

Authors
Kim, JHKim, KWGwon, DIKo, GYSung, KBLee, JShin, YMSong, GWHwang, SLee, SG
Issue Date
Jun-2011
Publisher
ELSEVIER SCIENCE INC
Citation
TRANSPLANTATION PROCEEDINGS, v.43, pp.1790 - 1793
Journal Title
TRANSPLANTATION PROCEEDINGS
Volume
43
Start Page
1790
End Page
1793
URI
http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/6006
DOI
10.1016/j.transproceed.2011.02.022
ISSN
0041-1345
Abstract
Purpose. To estimate the effect of splenic artery embolization (SAE) on blood flow in orthotopic liver transplantation (OLT) recipients with splenic artery steal syndrome (SASS) based on changes in caliber of related arteries upon serial computed tomography (CT) scans. Methods. Between 2004 and 2007, nine OLT recipients with SASS underwent SAE. They had CT scans before and after SAE: short-, mid-, and long-term, ie, approximately 1 week, 1 month, and 1 year, respectively. The diameters of the celiac axis (CA), common hepatic artery (CHA), and splenic artery (SA) were measured with arterial phase of each CT scan and the ratios of SA to CHA diameter (SA/CHA) calculated to analyze their changes during the follow-up period. Results. The diameters of celiac axis, CHA, and SA and SA/CHA changed most rapidly during the short-term period. The CHA diameter significantly increased short-term post-SAE by CT and slightly decreased thereafter. However, the mid-term and long-term post-SAE CT values were still significantly greater than those on the pre-SAE CT. The SA diameter steadily decreased throughout the follow-up. The SA/CHA decreased until the mid-term. The SA diameter and SA/CHA were significantly smaller upon mid-term and long-term post-SAE CT compared with those at pre-SAE CT. Conclusions. The effect of SAE to improve hepatic arterial flow in OLT recipients with SASS might be expected for at least approximately one year. The effect maximally occurred during the short-term after SAE on the basis of changes in the caliber of related arteries upon CT.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Information Technology > School of Computer Science and Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jeong Jin photo

Lee, Jeong Jin
College of Information Technology (School of Computer Science and Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE