벡터 제어 인버터 구동 원심펌프시스템의 에너지 절감 평가Evaluation of Energy Saving with Vector Control Inverter Driving Centrifugal Pump System
- Other Titles
- Evaluation of Energy Saving with Vector Control Inverter Driving Centrifugal Pump System
- Authors
- 서상호; 김경욱; 김형호; 윤인식; 조민태
- Issue Date
- Apr-2015
- Publisher
- 한국유체기계학회
- Keywords
- Inverter driving centrifugal pump system(인버터 구동 원심펌프시스템); Operation efficiency(운전효율); Variable speed drive(가변속 운전); Energy saving rate(에너지 절감율); Duty cycle(펌프 사용율)
- Citation
- 한국유체기계학회 논문집, v.18, no.2, pp.67 - 72
- Journal Title
- 한국유체기계학회 논문집
- Volume
- 18
- Number
- 2
- Start Page
- 67
- End Page
- 72
- URI
- http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/9155
- DOI
- 10.5293/kfma.2015.18.2.067
- ISSN
- 2287-9706
- Abstract
- The purpose of this study is to achieve energy saving effect of inverter driving multistage centrifugal pump. For determiningthe operation points in the pump system, the system curves should be obtained experimentally. To get the system curves, threepumps combined in parallel and one pump operated with different rotational speeds. But for variable speed pump system,energy saving rates can not be evaluated from operation efficiencies. That is why operation efficiencies, system curves, dutycycles, and input powers of the pump system were measured by the constructed experimental apparatus. The duty cyclesegmented into different flow rates and weighting the average value for each segment by the interval time. The system wasoperated with two different periods. The mean duty cycles were collected from apartment and found that the system operatedat 40% and at 50% or below capacity. Measured energy saving rate was 58.16%. Estimating method of energy saving rate couldbe more effective operation index than that of operation efficiency.
- Files in This Item
-
Go to Link
- Appears in
Collections - College of Engineering > ETC > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.