Detailed Information

Cited 3 time in webofscience Cited 3 time in scopus
Metadata Downloads

Ionization of Gas-Phase Polycyclic Aromatic Hydrocarbons in Electrospray Ionization Coupled with Gas Chromatography

Authors
Cha, EunjuJeong, Eun SookHan, Sang BeomCha, SangwonSon, JunghyunKim, SunghwanBin Oh, HanLee, Jaeick
Issue Date
Mar-2018
Publisher
AMER CHEMICAL SOC
Citation
ANALYTICAL CHEMISTRY, v.90, no.6, pp 4203 - 4211
Pages
9
Journal Title
ANALYTICAL CHEMISTRY
Volume
90
Number
6
Start Page
4203
End Page
4211
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/1062
DOI
10.1021/acs.analchem.8b00401
ISSN
0003-2700
1520-6882
Abstract
Herein, gas-phase polycyclic aromatic hydrocarbons (PAHs) as nonpolar compounds were ionized to protonated molecular ions [M + H](+) without radical cations and simultaneously analyzed using gas chromatography (GC)/electrospray ionization (ESI)-tandem mass spectrometry (MS/MS). The ionization profile, dissociation, and sensitivity were first investigated to understand the significant behavior of gas-phase PAHs under ESI. The formation of protonated molecular ions of PAHs was distinguished according to the analyte phase and ESI spray solvents. The protonated PAHs exhibited characteristic dissociations, such as H-loss, H-2-loss, and acetylene-loss, via competition of internal energy. In addition, GC/ESI-MS/MS resulted in relatively lower concentration levels (better sensitivity) for the limits-of-detection (LODs) of PAHs than liquid chromatography (LC)/ESI-MS/MS, and it seems to result from the characteristic ionization mechanism of the gas-phase analyte under ESI. Furthermore, the LODs of gas-phase PAHs depended on molecular weight and proton affinity (PA). Consequently, we demonstrated the relationship among the analyte phases, sensitivities, and structural characteristics (molecular weight and PA) under ESI. The gas-phase PAHs provided enhanced protonation efficiency and sensitivity using GC/ESI-MS/MS, as their molecular weight and PA increased. Based on these results, we offered important information regarding the behavior of gas-phase analytes under ESI. Therefore, the present GC/ESI-MS/MS method has potential as an alternative method for simultaneous analysis of PAHs.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Pharmacy > School of Pharmacy > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sang Beom photo

Han, Sang Beom
약학대학 (약학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE