Image reconstruction using voltage-current system in electrical impedance tomography

Authors
Kim, Bong SeokKhambampati, Anil KumarJang, Yeong JunKim, Kyung YounKim, Sin
Issue Date
Oct-2014
Publisher
ELSEVIER SCIENCE SA
Citation
NUCLEAR ENGINEERING AND DESIGN, v.278, pp 134 - 140
Pages
7
Journal Title
NUCLEAR ENGINEERING AND DESIGN
Volume
278
Start Page
134
End Page
140
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/11714
DOI
10.1016/j.nucengdes.2014.07.023
ISSN
0029-5493
Abstract
Electrical impedance tomography (EIT) has been used as an alternative imaging modality to visualize binary mixture like two-phase flows because of its high temporal resolution for monitoring fast transient processes. In this paper, voltage applied and current measured (VC) system based on complete electrode model is applied to image binary mixtures. The forward problem is formulated with the conductance matrix and a non-iterative inverse method is used to estimate the conductivity distribution. The proposed method with VC system needs simpler hardware as compared to conventional current applied and voltage measured system. Both numerical simulations and phantom experiments have been carried out to evaluate the performance of the proposed method through quantitative parameters. Results show a promising performance of VC system as an imaging modality for binary mixtures. (C) 2014 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Energy System Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Shin photo

Kim, Shin
공과대학 (에너지시스템 공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE