DICOM-based intravascular ultrasound signal intensity analysis: an Echoplaque Medical Imaging Bench study
- Authors
- Kim, Sang-Wook; Mintz, Gary S.; Lee, Wang-Soo; Cho, Jun Hwan; Hong, Soon Auck; Kwon, Jee Eun; Lee, Tae Jin; Park, Eon Sub; Park, Kyung Sook; Hong, Joon Hwa; Seok, Ju Won; Cha, Young Joo; Kim, Hyoung Joong; Kim, Chee Jeong; Kim, Tae Ho
- Issue Date
- May-2014
- Publisher
- LIPPINCOTT WILLIAMS & WILKINS
- Keywords
- intravascular ultrasound; plaque characterization; Digital Imaging and Communications in Medicine
- Citation
- CORONARY ARTERY DISEASE, v.25, no.3, pp 236 - 241
- Pages
- 6
- Journal Title
- CORONARY ARTERY DISEASE
- Volume
- 25
- Number
- 3
- Start Page
- 236
- End Page
- 241
- URI
- https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/12255
- DOI
- 10.1097/MCA.0000000000000077
- ISSN
- 0954-6928
1473-5830
- Abstract
- Background Most intravascular ultrasound (IVUS) data are stored digitally using the Digital Imaging and Communications in Medicine (DICOM) standard. This allows random access to studies and improves on the major limitation of conventional grayscale IVUS. Methods We harvested 129 coronary arteries from 43 autopsied cases. Grayscale IVUS and virtual histology-IVUS imaging were performed beginning 30 mm distal to the ostium of each coronary artery. Grayscale IVUS was processed; and the signal intensity was determined from DICOM-stored images using a new Medical Imaging Bench system (Echoplaque-MIB). We compared 436 regions of interest. The accuracy rate was expressed using the interpolation method and 95% confidence interval (CI). Results Patients' mean age was 49 +/- 9 years and 82% were men. Four patients succumbed to sudden cardiac death and 39 to noncardiac death. Grayscale IVUS signal intensity of dense calcium was 215 +/- 21.1 (95% CI: 207-223), that of fibrotic plaque was 75 +/- 17.8 (95% CI: 72-79), and that of fibrofatty plaque was 55 +/- 11.3 (95% CI: 52-59); however, the signal intensity of the necrotic core was between fibrotic plaque and dense calcium of 161 +/- 27.4 (95% CI: 153-168). Using the interpolation method, the cutoff values were as follows: fibrofatty plaque 0-65, fibrotic plaque 66-105, necrotic core 106-187, and dense calcium of at least 188. Overall, MIB grayscale had a 78.1% sensitivity and a 91.9% specificity versus histopathology. Conclusion Plaque characterization using DICOM-based grayscale IVUS signal intensity analysis may improve on the major limitation of conventional grayscale IVUS: its inability to assess plaque composition.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Medicine > College of Medicine > 1. Journal Articles
- College of Medicine > College of Medicine > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.