콘크리트 포장의 내구성 향상을 위한 양생제 시공기술 최적화 연구A Study on the Optimization of Curing Technology for Improving Properties of Concrete Pavement
- Authors
- Park, Kwon Jea; Ryu, Sung Woo; Kim, Hyung Bae; Joo, Young Min; Cho, Yoon-Ho
- Issue Date
- 2013
- Publisher
- 한국도로학회
- Keywords
- curing compound; ratio of water loss; abrasion resistance; concrete pavement
- Citation
- 한국도로학회논문집, v.15, no.5, pp 11 - 20
- Pages
- 10
- Journal Title
- 한국도로학회논문집
- Volume
- 15
- Number
- 5
- Start Page
- 11
- End Page
- 20
- URI
- https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/19433
- ISSN
- 1738-7159
2287-3678
- Abstract
- PURPOSES : This study is to suggest time to spray curing compound, the amount of curing compound, and the number of times to spray curing compound based on indoor tests.
METHODS: Based on the literature review, two methods are used in this study, One is test for water retention of concrete curing material and the other is test for abrasion resistance of concrete surfaces by the rotating-cutter method. Through those methods, curing compound was evaluated.
RESULTS : The result of the laboratory experiment for time to spray curing compound indicates that 30 minutes after placing concrete is optimal. For the amount of curing compound, 0.5ℓ/m2 is the minimum quantity for both concretes. Through test of the number of times to spray curing compound, method to spray the whole amount of curing compound in twice is more efficient than it to spray the whole amount at a time. Also, method of separately 30-50 minutes spray is better than method of separately 10-30 minutes spray.
CONCLUSIONS : From the testing results, it can be proposed that optimum time to curing compound is 30±15 minutes, 0.5ℓ/m2 is efficient for spraying the whole amount of curing compound at a time, and 0.4ℓ/m2 is the best for spraying the whole amount of curing compound in twice, which sprays it in 20 minutes after 30 minutes from placing concrete.
PURPOSES : This study is to suggest time to spray curing compound, the amount of curing compound, and the number of times to spray curing compound based on indoor tests.
METHODS: Based on the literature review, two methods are used in this study, One is test for water retention of concrete curing material and the other is test for abrasion resistance of concrete surfaces by the rotating-cutter method. Through those methods, curing compound was evaluated.
RESULTS : The result of the laboratory experiment for time to spray curing compound indicates that 30 minutes after placing concrete is optimal. For the amount of curing compound, 0.5ℓ/m2 is the minimum quantity for both concretes. Through test of the number of times to spray curing compound, method to spray the whole amount of curing compound in twice is more efficient than it to spray the whole amount at a time. Also, method of separately 30-50 minutes spray is better than method of separately 10-30 minutes spray.
CONCLUSIONS : From the testing results, it can be proposed that optimum time to curing compound is 30±15 minutes, 0.5ℓ/m2 is efficient for spraying the whole amount of curing compound at a time, and 0.4ℓ/m2 is the best for spraying the whole amount of curing compound in twice, which sprays it in 20 minutes after 30 minutes from placing concrete.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Engineering > ETC > 1. Journal Articles
![qrcode](https://api.qrserver.com/v1/create-qr-code/?size=55x55&data=https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/19433)
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.