Detailed Information

Cited 0 time in webofscience Cited 4 time in scopus
Metadata Downloads

Measurement of strabismic angle using the distance Krimsky testopen accessMeasurement of Strabismic Angle Using the Distance Krimsky Test

Authors
Joo, K.S.Koo, H.Moon, N.J.
Issue Date
Aug-2013
Publisher
대한안과학회
Keywords
Distance Krimsky test; Esotropia; Exotropia; Strabismus
Citation
Korean journal of ophthalmology : KJO, v.27, no.4, pp 276 - 281
Pages
6
Journal Title
Korean journal of ophthalmology : KJO
Volume
27
Number
4
Start Page
276
End Page
281
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/19833
DOI
10.3341/kjo.2013.27.4.276
ISSN
1011-8942
2092-9382
Abstract
To evaluate the correlation of the distance Krimsky test and the alternate prism cover test (APCT) for the distance deviation in patients with horizontal strabismus. Forty patients with horizontal strabismus (20 esotropia and 20 exotropia) were included in this study. Patients with a variable angle of deviation, vertical angle over 5 prism diopters, impaired binocular vision, or poor cooperation were excluded. We instructed the patient to look a target 6 meters away, and applied a prism over the patient's dominant eye while flashing a light source 33 centimeters from the middle of both eyebrows. When the corneal light reflexes were located on the center of each cornea, we measured the angle of deviation. We defined this method as 'distance Krimsky test,' and the angle measured by this method was compared with the conventional Krimsky test and APCT at distance. We analyzed the accuracy and intra- and inter-observer reliability. The angle of strabismus measured by the distance Krimsky test showed a significant agreement and correlation with the deviation angle measured by the APCT. We elicited the correlation gradient between the angle measured by the distance Krimsky test and the APCT. In addition, the distance Krimsky test showed significant intra- and inter-observer reliabilities. The distance Krimsky test is expected to be more useful than the Krimsky test in measuring the distance angle of deviation for patients with strabismus in whom it is difficult to measure the angle of deviation using the APCT. The distance Krimsky test can be an accurate and useful test through the improvement of proficiency of examiners and the establishment of individualized normative data.
Files in This Item
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Moon, Nam Ju photo

Moon, Nam Ju
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE