Detailed Information

Cited 53 time in webofscience Cited 62 time in scopus
Metadata Downloads

Resistance of pathogenic bacteria on the surface of stainless steel depending on attachment form and efficacy of chemical sanitizers

Authors
Bae, Young-MinBaek, Seung-YoubLee, Sun-Young
Issue Date
Feb-2012
Publisher
ELSEVIER SCIENCE BV
Keywords
Biofilm; Foodborne pathogen; Resistance; Attached form; Chemical sanitizer
Citation
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, v.153, no.3, pp 465 - 473
Pages
9
Journal Title
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY
Volume
153
Number
3
Start Page
465
End Page
473
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/20508
DOI
10.1016/j.ijfoodmicro.2011.12.017
ISSN
0168-1605
1879-3460
Abstract
Various bacteria including food spoilage bacteria and pathogens can form biofilms on different food processing surfaces, leading to potential food contamination or spoilage. Therefore, the survival of foodborne pathogens (Escherichia coli 0157:H7, Listeria monocytogenes, Salmonella typhimurium, Staphylococcus aureus, Cronobacter sakazakii) in different forms (adhered cells, biofilm producing in TSB, biofilm producing at RH 100%) on the surface of stainless steel and stored at various relative humidities (RH 23%, 43%, 68%, 85%, and 100%) at room temperature for 5 days was investigated in this study. Additionally, the efficacy of chemical sanitizers (chlorine-based and alcohol-based commercial sanitizers) on inhibiting various types of biofilms of E. coli 0157:H7 and S. aureus on the surface of stainless steel was investigated. The number of pathogens on the surface of stainless steel in TSB stored at 25 degrees C for 7 days or RH 100% at 25 degrees C for 7 days was significantly increased and resulted in the increase of 3 log(10) CFU/coupon after 1 day, and these levels were maintained for 7 days. When stainless steel coupons were stored at 25 degrees C for 5 days, the number of pathogens on the surface of stainless steel was significantly reduced after storage at RH 23%, 43%, 68%, and 85%, but not at 100%. When the bacteria formed biofilms on the surface of stainless steel in TSB after 6 days, the results were similar to those of the attached form. However, levels of S. aureus and C sakazakii biofilms were more slowly reduced after storage at RH 23%, 43%, 68%, and 85% for 5 days than were those of the other pathogens. Formation of biofilms stored at RH 100% for 5 days displayed the highest levels of resistance to inactivation. Treatment with the alcohol sanitizer was very effective at inactivating attached pathogens or biofilms on the surface of stainless steel. Reduction levels of alcohol sanitizer treatment ranged from 1.91 to 4.77 log and from 4.35 to 5.35 log CFU/coupon in E. coli 0157:H7 and S. aureus, respectively. From these results, the survival of pathogens contaminating the surfaces of food processing substrates such as stainless steel varied depending on RH and attachment form. Also, alcohol-based sanitizers can be used as a potential method to remove microbial contamination on the surfaces of utensils, cooking equipment, and other related substrates regardless of the microbial attached form. (C) 2012 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Biotechnology & Natural Resource > School of Food Science and Technology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Sun Young photo

Lee, Sun Young
생명공학대학 (식품영양)
Read more

Altmetrics

Total Views & Downloads

BROWSE