Detailed Information

Cited 2 time in webofscience Cited 0 time in scopus
Metadata Downloads

Novel Parameter for the Diagnosis of Distal Middle Cerebral Artery Stenosis with Transcranial Doppler Sonography

Authors
Ahn, Suk-WonPark, Sang-SoonLee, Yong-Seok
Issue Date
Oct-2010
Publisher
WILEY
Keywords
transcranial Doppler; middle cerebral artery stenosis; TCD; MCA infarction; MCA stenosis
Citation
JOURNAL OF CLINICAL ULTRASOUND, v.38, no.8, pp 420 - 425
Pages
6
Journal Title
JOURNAL OF CLINICAL ULTRASOUND
Volume
38
Number
8
Start Page
420
End Page
425
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/22165
DOI
10.1002/jcu.20711
ISSN
0091-2751
1097-0096
Abstract
Purpose. Transcranial Doppler sonography (TCD) is commonly used for the diagnosis of middle cerebral artery (MCA) stenosis. However, TCD indices to predict distal MCA (M2) stenosis have not yet been established. We compared TCD and magnetic resonance angiography (MRA) to validate a new index for the diagnosis of M2 stenosis. Methods. Consecutive patients who underwent TCD and MRA were included. Based on MRA, M2 stenosis was defined as >50% narrowing beyond the bifurcation area. TCD index of the M2/M1 ratio was defined as the ratio between the mean flow velocity (MFV) obtained at a depth of 30-44 mm (M2) and a depth of 45-65 mm (M1). Sensitivity and specificity of the M2/M1 ratio were calculated from the receiver operating characteristic curve. The diagnostic yield of elevated MFV (>80 cm/s) and asymmetry index of >30% for M2 stenosis were also investigated. Results. Among the consecutive patients, 105 with M2 stenosis were compared with 123 without MCA stenosis. The M2/M1 ratio was significantly higher in the M2 stenosis group (1.10 versus 0.86, p < 0.001). Sensitivity and specificity for M2 stenosis were most satisfying when the M2/M1 ratio of 0.97 was adopted as the cutoff value. Diagnostic yield of the M2/M1 ratio was better than MFV or asymmetry index. Conclusions. The M2/M1 ratio may be a highly specific parameter for assessing M2 stenosis with TCD. (C) 2010 Wiley Periodicals, Inc. J Clin Ultrasound 38:420-425, 2010; Published online in Wiley Online Library (wileyonlinelibrary.com). DOI: 10.1002/jcu.20711
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ahn, Suk Won photo

Ahn, Suk Won
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE