Detailed Information

Cited 12 time in webofscience Cited 0 time in scopus
Metadata Downloads

Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of goserelin in rabbit plasma

Authors
Kim, Min KyungLee, Tae HoSuh, Joon HyukEom, Han YoungMin, Jung WonYeom, HyesunKim, UnyongJung, Hyung JoonCha, Kyung HoiChoi, Yong SeokYoum, Jeong-RokHan, Sang Beom
Issue Date
Aug-2010
Publisher
ELSEVIER SCIENCE BV
Keywords
Goserelin; Peptide; Liquid chromatography-tandem mass spectrometry; Rabbit plasma; Pharmacokinetic study
Citation
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, v.878, no.24, pp 2235 - 2242
Pages
8
Journal Title
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
Volume
878
Number
24
Start Page
2235
End Page
2242
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/22262
DOI
10.1016/j.jchromb.2010.06.031
ISSN
1570-0232
1873-376X
Abstract
A rapid and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the determination of goserelin in rabbit plasma. Various parameters affecting plasma sample preparation, LC separation, and MS/MS detection were investigated, and optimized conditions were identified. Acidified plasma samples were applied to Oasis (R) HLB solid-phase extraction (SPE) cartridges. Extracted samples were evaporated under a stream of nitrogen and then reconstituted with 100 mu L mobile phase A. The separation was achieved on a Capcell-Pak C18 (2.0 mm x 150 mm, 5 mu m, AQ type) column with a gradient elution of solvent A(0.05% acetic acid in deionized water/acetonitrile = 85/15; v/v) and solvent B (acetonitrile) at a flow rate of 250 mu L/min. The LC-MS/MS system was equipped with an electrospray ion source operating in positive ion mode. Multiple-reaction monitoring (MRM) of the precursor-product ion transitions consisted of m/z 635.7 -> m/z 607.5 for goserelin and m/z 424.0 -> m/z 292.1 for cephapirin (internal standard). The proposed method was validated by assessing specificity, linearity, limit of quantification (LOQ), intra-and inter-day precision and accuracy, recovery, and stability. Linear calibration curves were obtained in the concentration range of 0.1-20 ng/mL (the correlation coefficients were above 0.99). The LOQ of the method was 0.1 ng/mL Results obtained from the validation study of goserelin showed good accuracy and precision at concentrations of 0.1, 1, 5, 10, and 20 ng/mL. The validated method was successfully applied to a pharmacokinetic study of goserelin after a single subcutaneous injection of 3.6 mg of goserelin in healthy white rabbits. (C) 2010 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Pharmacy > School of Pharmacy > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sang Beom photo

Han, Sang Beom
약학대학 (약학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE