Comparison between evaporative light scattering detection and charged aerosol detection for the analysis of saikosaponins

Authors
Eom, Han YoungPark, So-YoungKim, Min KyungSuh, Joon HyukYeom, HyesunMin, Jung WonKim, UnyongLee, JeongmiYoum, Jeong-RokHan, Sang Beom
Issue Date
Jun-2010
Publisher
ELSEVIER SCIENCE BV
Keywords
Charged aerosol detection (CAD); Evaporative light scattering detection (ELSD); Saikosaponins; Bupleuri Radix
Citation
JOURNAL OF CHROMATOGRAPHY A, v.1217, no.26, pp 4347 - 4354
Pages
8
Journal Title
JOURNAL OF CHROMATOGRAPHY A
Volume
1217
Number
26
Start Page
4347
End Page
4354
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/22374
DOI
10.1016/j.chroma.2010.04.047
ISSN
0021-9673
1873-3778
Abstract
Saikosaponins are triterpene saponins derived from the roots of Bupleurum falcatum L. (Umbelliferae), which has been traditionally used to treat fever, inflammation, liver diseases, and nephritis. It is difficult to analyze saikosaponins using HPLC-UV due to the lack of chromophores. Therefore, evaporative light scattering detection (ELSD) is used as a valuable alternative to UV detection. More recently, a charged aerosol detection (CAD) method has been developed to improve the sensitivity and reproducibility of ELSD. In this study, we compared CAD and ELSD methods in the simultaneous analysis of 10 saikosaponins, including saikosaponins-A, -B-1, -B-2, -B-3, -B-4, -C, -D, -G, -H and -I. A mixture of the 10 saikosaponins was injected into the Ascentis (R) Express C18 column (100 mm x 4.6 mm, 2.7 mu m) with gradient elution and detection with CAD and ELSD by splitting. We examined various factors that could affect the sensitivity of the detectors including various concentrations of additives, pH and flow rate of the mobile phase, purity of nitrogen gas and the CAD range. The sensitivity was determined based on the signal-to-noise ratio. The best sensitivity for CAD was achieved with 0.1 mM ammonium acetate at pH 4.0 in the mobile phase with a flow rate of 1.0 mL/min, and the CAD range at 100 pA, whereas that for ELSD was achieved with 0.01% acetic acid in the mobile phase with a flow rate at 0.8 mL/min. The purity of the nitrogen gas had only minor effects on the sensitivities of both detectors. Finally, the sensitivity for CAD was two to six times better than that of ELSD. Taken together, these results suggest that CAD provides a more sensitive analysis of the 10 saikosaponins than does ELSD. (c) 2010 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Pharmacy > School of Pharmacy > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sang Beom photo

Han, Sang Beom
약학대학 (약학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE