Detailed Information

Cited 10 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of Release-Controlling Efficiency of Polymeric Coating Materials Using Matrix-type Casted Films and Diffusion-Controlled Coated Tablet

Authors
Piao, Zong-ZhuLee, Kyoung-HoKim, Dong-JinLee, Hong-GuLee, JaehwiOh, Kyung TaekLee, Beom-Jin
Issue Date
Jun-2010
Publisher
SPRINGER
Keywords
diffusion-controlled coated tablet; drug release rate; matrix-type casted film; polymeric coating materials; release-controlling power
Citation
AAPS PHARMSCITECH, v.11, no.2, pp 630 - 636
Pages
7
Journal Title
AAPS PHARMSCITECH
Volume
11
Number
2
Start Page
630
End Page
636
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/22447
DOI
10.1208/s12249-010-9377-0
ISSN
1530-9932
1522-1059
Abstract
Polymeric coating materials have been widely used to modify release rate of drug. We compared physical properties and release-controlling efficiency of polymeric coating materials using matrix-type casted film and diffusion-controlled coated tablet. Hydroxypropylmethyl cellulose (HPMC) with low or high viscosity grade, ethylcellulose (EC) and EudragitA (R) RS100 as pH-independent polymers and Eudragit S100 for enteric coatings were chosen to prepare the casted film and coated tablet. Tensile strength and contact angle of matrix-type casted film were invariably in the decreasing order: EC > Eudragit S100 > HPMC 100000 > Eudragit RS100 > HPMC 4000. There was a strong linear correlation between tensile strength and contact angle of the casted films. In contrast, weight loss (film solubility) of the matrix-type casted films in three release media (gastric, intestinal fluid and water) was invariably in the increasing order: EC < HPMC 100000 < Eudragit RS100 < HPMC 4000 with an exception of Eudragit S100. The order of release rate of matrix-type casted films was EC > HPMC 100000 > Eudragit RS100 > HPMC 4000 > Eudragit S100. Interestingly, diffusion-controlled coated tablet also followed this rank order except Eudragit S100 although release profiles and lag time were highly dependent on the coating levels and type of polymeric coating materials. EC and Eudragit RS100 produced sustained release while HPMC and Eudragit S100 produced pulsed release. No molecular interactions occurred between drug and coating materials using H-1-NMR analysis. The current information on release-controlling power of five different coating materials as matrix carrier or diffusion-controlled film could be applicable in designing oral sustained drug delivery.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Pharmacy > School of Pharmacy > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Kyung Taek photo

Oh, Kyung Taek
대학원 (글로벌혁신신약학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE