Detailed Information

Cited 52 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effects of audio tone guidance on performance of CPR in simulated cardiac arrest with an advanced airway

Authors
Oh, Je HyeokLee, Sang JinKim, Sung EunLee, Kwang JungChoe, Ju WonKim, Chan Woong
Issue Date
Nov-2008
Publisher
ELSEVIER IRELAND LTD
Keywords
Cardiopulmonary resuscitation (CPR); Chest compression; Ventilation; Feedback; Quality control
Citation
RESUSCITATION, v.79, no.2, pp 273 - 277
Pages
5
Journal Title
RESUSCITATION
Volume
79
Number
2
Start Page
273
End Page
277
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/23559
DOI
10.1016/j.resuscitation.2008.06.022
ISSN
0300-9572
1873-1570
Abstract
The aim of the study: Despite the emphasis of cardiopulmonary resuscitation (CPR) quality, the performance of on-site CPR is reported to be frequently unsuccessful. In order to improve CPR quality, various feedback systems have been developed, but they have not yet been widely used on site due to low economic efficiency. The present study was attempted to determine whether CPR quality can be improved using audio tone guidance. The methods: A total of 80 seniors at our medical school and college of nursing participated in the study. After they were trained in CPR according to the 2005 guidelines, they performed CPR using a cardiac arrest model with an advanced airway. The participants were organized into 40 groups. After they took Test 1 without any feedback for 2 min, they were randomly assigned to the feedback and control groups and took Test 2 for 2 min. In the feedback group, a low-pitched sound was delivered every 0.6 s for the guidance of chest compression and a high-pitched sound was simultaneously delivered every 10 deliveries of a tow-pitched sound for the guidance of ventilation at 6 s intervals. The results: In the feedback group the mean compression rate significantly improved in accuracy from 111.5 +/- 13.7/min to 100.1 +/- 3.2/min (P<0.01), and ventilation counts significantly improved in accuracy from 7.4 +/- 1.8/min to 9.9 0.3/min (P<0.01). However, the mean compression depth significantly decreased from 39.3 +/- 9.5 mm to 35.8 +/- 8.2 mm (P<0.01). The conclusion: Audio tone guidance ensures better chest compression rate and ventilation rate but this does not necessarily result in a better CPR quality. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Je Hyeok photo

Oh, Je Hyeok
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE