Detailed Information

Cited 11 time in webofscience Cited 16 time in scopus
Metadata Downloads

Sensitive determination of erdosteine in human plasma by use of automated 96-well solid-phase extraction and LC-MS/MS

Authors
Kim, HYChang, KYLee, HJHan, SBLee, KR
Issue Date
Feb-2004
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
tandem mass spectrometry; liquid chromatography; 96-well solid-phase extraction; erdosteine; letosteine
Citation
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, v.34, no.3, pp 661 - 669
Pages
9
Journal Title
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
Volume
34
Number
3
Start Page
661
End Page
669
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/24877
DOI
10.1016/j.jpba.2003.11.003
ISSN
0731-7085
1873-264X
Abstract
A sensitive and selective method for quantitation of erdosteine in human plasma was established by use of 96-well solid-phase extraction (SPE) and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Plasma samples were transferred into 96-well OASIS HLB extraction plate using an automated sample handling system and the drugs were eluted with methanol. The eluents were then evaporated and reconstituted with mobile phase. All sample transfer and SPE was automated through the application of both the Perkin-Elmer MultiPROBE II HT and TOMTEC Quadra 96 workstation. Compounds were separated on a C-18 column with 1 mM ammonium acetate-acetonitrile (80:20, pH 3.2), as mobile phase at a flow rate of 0.3 ml/min. The limit of quantitation (LOQ) was 0.2 ng/ml, using a sample volume of 0.2 ml for the analysis. The reproducibility of the method was evaluated by analyzing three at 14 quality control (QC) levels over the nominal concentration range from 0.2 to 5000 ng/ml. The intraday accuracy was found to range from 99.6 to 105.0% with precision (% RSD) of less than 4.76% at five QC levels. The interday accuracy was found to range from 95.0 to 100.5% with precision of less than 5.26% at five QC levels. Erdosteine produced a protonated precursor ion ([M +H](+)) at m/z 250, and a corresponding product ion at m/z 204. Internal standard (letosteine) produced a protonated precursor ion ([M + H](+)) at m/z 280 and a corresponding product ion at m/z 160. The high sample throughput of the method has been successfully applied to a pharmacokinetic study of erdosteine in human plasma. (C) 2003 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sang Beom photo

Han, Sang Beom
약학대학 (약학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE