Detailed Information

Cited 7 time in webofscience Cited 7 time in scopus
Metadata Downloads

Characteristics of a transverse-type Compton-suppressed gamma-ray detector

Authors
Lee, CSKwon, YKLee, JHKim, JHKim, JYMoon, JY
Issue Date
May-2002
Publisher
KOREAN PHYSICAL SOC
Keywords
gamma-ray detector; Compton-suppressed detector; BGO; cyclotron
Citation
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.40, no.5, pp 807 - 811
Pages
5
Journal Title
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
Volume
40
Number
5
Start Page
807
End Page
811
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/25119
ISSN
0374-4884
Abstract
The performance of a Compton-suppressed gamma-ray detector using a transverse escape-suppression shield of BGO was analyzed by measuring two relevant factors, the suppression ratio and the peak-to-total ratio. The suppression ratio varied from 2 to 6, depending on gamma-ray energy as two standard sources. Co-60 and Cs-137, were used. The peak-to-total ratio was improved by a factor of two or more when the escape shield was used. The suppression ratio of our detector was shown to be comparable to that of a Stony-Brook detector of a similar type.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Natural Sciences > Department of Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.