Detailed Information

Cited 0 time in webofscience Cited 18 time in scopus
Metadata Downloads

Evaluation of BCB bonded and thinned wafer stacks for three-dimensional integration

Authors
Kwon, Y.Jindal, A.Augur, R.Seok, J.Cale, T.S.Gutmann, R.J.Lu, J.-Q.
Issue Date
2008
Citation
Journal of the Electrochemical Society, v.155, no.5, pp H280 - H286
Journal Title
Journal of the Electrochemical Society
Volume
155
Number
5
Start Page
H280
End Page
H286
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/25612
DOI
10.1149/1.2844449
ISSN
0013-4651
Abstract
A critical issue associated with the implementation of wafer-level three-dimensional (3D) integration is to achieve excellent bonding and thinning performance without degrading mechanical and electrical characteristics of integrated circuit (IC) chips in the 3D wafer stack. In this work, some mechanical and electrical impacts of wafer bonding and thinning processes used to fabricate 3D ICs are evaluated using patterned wafers with two-level copper interconnect test structures that included either silicon dioxide or porous low- k interlevel dielectrics (ILDs). Benzocyclobutene (BCB) (Cyclotene 3022-35 from Dow Chemical) is the adhesive used, and thinning consists of grinding, chemical mechanical polishing, and wet etching. Three procedures used to evaluate the integrity of BCB bonded and thinned wafer stacks are discussed: (i) optical inspection of the bonding interface using glass wafers with a coefficient of thermal expansion that is close to that of silicon wafers in order to check for voids, defects, and uniformity after each bonding and thinning process; (ii) four-point bending tests to quantify bond strength and to identify the weak bond interface, and (iii) electrical tests of the patterned wafers after two bonding and thinning processes and subsequent BCB removal by plasma ashing to expose the contact pads. These procedures evaluated the impacts of processing of wafer stacks without the need for interwafer interconnect processing. Some negative mechanical and electrical impacts were observed for interconnect structures that include a porous low- k ILD, while no significant changes were observed for interconnect structures with oxide ILD. © 2008 The Electrochemical Society.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seok, Jong Won photo

Seok, Jong Won
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE