Detailed Information

Cited 3 time in webofscience Cited 3 time in scopus
Metadata Downloads

Online turbulent flow extraction coupled with liquid chromatography-tandem mass spectrometry for high throughput screening of anabolic steroids in horse urine

Authors
Shin, Hyun DuSuh, Joon HyukKim, JunghyunCho, Hyun-DeokLee, Su DukHan, Kwan SeokWang, YuHan, Sang Beom
Issue Date
Oct-2017
Publisher
ELSEVIER SCIENCE BV
Keywords
Androgenic anabolic steroids; Horse urine; Turbulent flow chromatography; Mass spectrometry; Doping control
Citation
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, v.145, pp 46 - 51
Pages
6
Journal Title
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
Volume
145
Start Page
46
End Page
51
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/3763
DOI
10.1016/j.jpba.2017.06.036
ISSN
0731-7085
1873-264X
Abstract
A high throughput method for simultaneous screening of anabolic steroids and their metabolites (4-esterendione, trenbolone, boldenone, oxandrolone, nandrolone, methandrostenolone, testosterone, 1-androstendione, ethisterone, normethandrolone, methyltestosterone, 16 beta-Hydroxystanozolol, epitestosterone, bolasterone, norethandrolone, danazol, stanozolol and androstadienone) in equine urine by online turbulent flow extraction coupled with liquid chromatography-tandem mass spectrometry was developed. The use of turbulent flow chromatography could simplify pretreatment of horse urine, which has complex matrices as well as high viscosity. The urine was extracted by mixed-mode cation exchange solid phase extraction, and hydrolyzed using beta-glucuronidase/atylsulfatase. Then, the sample was automatically loaded on the TurboFlow Cyclone extraction column for removal of further matrix, followed by separation on a fused core C18 column before MS/MS detection. Optimization and validation of the method were discussed in detail. All analytes were rapidly detected within 10 min with high sensitivity (picogram to nanogram per milliliter level), and no interference was observed. The linearity range was from 0.1-10 ng/mL for nine steroids and 1.0-50 ng/mL for the others, with correlation of coefficient values over 0.995. Precision and accuracy ranged from 0.1 to 14.5% and 1.7 to 12.4%, respectively. The developed method was successfully applied to the analysis of anabolic steroids in horse urine after administration of a model drug. (C) 2017 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Pharmacy > School of Pharmacy > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sang Beom photo

Han, Sang Beom
약학대학 (약학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE