Detailed Information

Cited 1 time in webofscience Cited 0 time in scopus
Metadata Downloads

Wave-CAIPI susceptibility-weighted imaging achieves diagnostic performance comparable to conventional susceptibility-weighted imaging in half the scan time

Authors
Chung, Mi SunLee, Eun JungKim, SujinKim, Seon-OkByun, Jun Soo
Issue Date
Apr-2020
Publisher
SPRINGER
Keywords
Magnetic resonance imaging; Brain; Hemorrhage; Diagnostic imaging
Citation
EUROPEAN RADIOLOGY, v.30, no.4, pp 2182 - 2190
Pages
9
Journal Title
EUROPEAN RADIOLOGY
Volume
30
Number
4
Start Page
2182
End Page
2190
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/38005
DOI
10.1007/s00330-019-06574-1
ISSN
0938-7994
1432-1084
Abstract
Objectives We aimed to evaluate the agreement in the detection of cerebral microbleeds (CMBs) between conventional susceptibility-weighted imaging (SWI) and fast SWI using wave-controlled aliasing in parallel imaging (CAIPI) acceleration. We also scrutinized the diagnostic agreement for intracranial lesions and compared the image quality between both sequences. Methods Institutional review board approval was obtained and informed consent was waived for this retrospective study. We included 181 consecutive patients who had undergone brain MRI with both conventional SWI (scan time, 251 s) and wave-CAIPI SWI (scan time, 113 s) from September 2017 to November 2017. All images were independently reviewed by two radiologists for the detection and counting of CMBs using the Microbleed Anatomical Rating Scale (MARS). One neuroradiologist diagnosed intracranial lesions and scored image quality using visual analysis. The agreement for detection of CMBs and intracranial lesions was calculated, and interobserver agreements were analyzed by using kappa and intraclass correlation. Results For detection of CMBs, both the conventional and wave-CAIPI SWI showed significantly high agreement of 100% for the presence of CMBs, and 94.5% using MARS. Wave-CAIPI SWI achieved more than 97% agreement of MARS when divided by anatomical locations, with excellent agreement. Interobserver agreements were also excellent. The diagnosis for intracranial lesions (33 lesions in 28 patients) demonstrated 100% agreement. The image quality of both sequences is not significantly different (p = 0.20). Conclusions Wave-CAIPI SWI achieved high agreement for CMB detection and diagnosis of intracranial lesions compared to conventional SWI within half of the scan time.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Sujin photo

Kim, Sujin
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE