Detailed Information

Cited 3 time in webofscience Cited 3 time in scopus
Metadata Downloads

Clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents versus durable polymer everolimus-eluting Xience stentsopen access

Authors
Lee, Da HyonPark, Taek KyuSong, Young BinChun, Woo JungChoi, Rak KyeongJeong, Jin-OkIm, Eul SoonKim, Sang WookLee, Joo MyungYang, Jeong HoonHahn, Joo-YongChoi, Seung-HyukChoi, Jin-HoLee, Sang HoonGwon, Hyeon-Cheol
Issue Date
Aug-2017
Publisher
PUBLIC LIBRARY SCIENCE
Citation
PLOS ONE, v.12, no.8
Journal Title
PLOS ONE
Volume
12
Number
8
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/4087
DOI
10.1371/journal.pone.0183079
ISSN
1932-6203
Abstract
There are limited data about clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents (BP-BES) and durable polymer everolimus-eluting Xience stents (DP-EES) in real world practice. We sought to compare the clinical outcomes of BP-BES and DP-EES in real world cohorts of patients undergoing percutaneous coronary intervention. A prospective multicenter registry enrolled 999 patients treated with BP-BES and 1,000 patients treated with DP-EES. The primary outcome was target lesion failure, defined as a composite of cardiac death, target vessel-related myocardial infarction, or target lesion revascularization. Definite or probable stent thrombosis was also compared in total and propensity score-matched cohorts. The median follow-up duration was 24 months, and mean age was 65 years (interquartile range, 56-72 years). Patients receiving BP-BES had a lower prevalence of acute coronary syndrome, prior myocardial infarction, multi-vessel disease, bifurcation lesions, and left anterior descending artery lesions than those receiving DP-EES. After propensity score matching (692 pairs), target lesion failure occurred in 22 patients receiving BP-BES and in 25 patients receiving DP-EES (3.2% versus 3.6%; adjusted hazard ratio [HR], 0.92; 95% confidence interval [CI], 0.53 to 1.60; p = 0.77). The risk of definite or probable stent thrombosis did not differ between the 2 groups (0.4% versus 0.4%; adjusted HR, 1.03; 95% CI, 0.21 to 4.98; p = 0.97). The results were consistent across various subgroups. In the propensity score-matched analysis of real world cohorts, BP-BES showed similar clinical outcomes compared to DP-EES. We need to investigate about whether differences in clinical outcome emerge during long-term follow-up.
Files in This Item
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Sang Wook photo

Kim, Sang Wook
의과대학 (의학부(임상-광명))
Read more

Altmetrics

Total Views & Downloads

BROWSE