Detailed Information

Cited 9 time in webofscience Cited 11 time in scopus
Metadata Downloads

Performance analysis of vapor injection heat pump system for electric vehicle in cold startup condition

Authors
Choi, Young UkKim, Mo SeKim, Gwi TaekKim, MinsungKim, Min Soo
Issue Date
Aug-2017
Publisher
ELSEVIER SCI LTD
Keywords
Vapor injection; Heat pump; Electric vehicle; Scroll compressor; Intermediate pressure; Optimal injection strategy
Citation
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, v.80, pp 24 - 36
Pages
13
Journal Title
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID
Volume
80
Start Page
24
End Page
36
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/4153
DOI
10.1016/j.ijrefrig.2017.04.026
ISSN
0140-7007
1879-2081
Abstract
In this study, a vapor-injection (VI) cycle designed for indoor heating of electric vehicle (EV) was investigated for low temperature heating purposes. The heating capacity variation was observed both in mathematical and experimental ways to verify the influence of vapor injection at different injecting positions and under different intermediate pressure. From this study, the optimal injection position of the scroll compressor and intermediate pressure ratio were evaluated that maximizes heating capacity and coefficient of performance (COP) of the cycle. To validate the numerical results, the experiment was also conducted in the prototype of a vapor-injection (VI) heating system for electric vehicle. The experiment was carried out under the steady-state condition and the same parameters as those of numerical analysis were employed. The comparison between the results of numerical analysis and that of experiments showed a good agreement. For the increase of heating capacity, the optimal injecting port position was observed in specific value which was close to 300. As the opening of the main expansion valve was decreased, the performance of the VI system generally got better but the system had much restricted intermediate pressure ratio in which the performance was drastically decreased. As a result, the optimal intermediate pressure ratio occurred in specific value below 0.25 in startup condition. (C) 2017 Elsevier Ltd and IIR. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Energy System Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Min Sung photo

Kim, Min Sung
대학원 (지능형에너지산업융합학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE