Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Multiresidue analysis of 85 persistent organic pollutants in small human serum samples by modified QuEChERS preparation with different ionization sources in mass spectrometry

Authors
Lee J.E.Oh H.B.Im H.Han S.B.Kim K.H.
Issue Date
19-Jul-2020
Publisher
Elsevier B.V.
Keywords
Atmospheric pressure chemical ionization; Electron impact ionization; Human serum; Persistent organic pollutants; QuEChERS
Citation
Journal of Chromatography A, v.1623
Journal Title
Journal of Chromatography A
Volume
1623
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/42669
DOI
10.1016/j.chroma.2020.461170
ISSN
0021-9673
1873-3778
Abstract
In this study, a multiresidue analytical method was developed, validated, and applied for quantifying 85 persistent organic pollutants (POPs), including 38 polychlorinated biphenyls (PCBs), 23 polybrominated diphenyl ethers (PBDEs), and 24 organochlorine pesticides (OCPs) from 200 μL of human serum. A modified QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) method was applied to minimize the required sample amount and optimize various conditions including the extraction solvent and the number of extractions. The extraction efficiency was optimized using double extraction with an ethyl acetate/hexane/acetone mixture. Gas chromatography coupled with triple-quadrupole mass spectrometry was used for analysis, and two different ionization sources, electron impact ionization (EI) and atmospheric pressure chemical ionization (APCI), were used to compare their sensitivity. The APCI source employed soft ionization at atmospheric pressure, producing abundant molecular ion formation with minimal fragmentation, in contrast to extensive fragmentation caused by EI. Of the 85 POPs analyzed, 59 target compounds (69.4%) showed lower limits of detection that were two- to fifty-fold lower in APCI than those determined using EI. The developed method was validated for its detection limit (0.5–10 pg/mL for PCBs, 2–20 pg/mL for PBDEs, and 2–40 pg/mL for OCPs), precision (0.8%–34.3% of coefficient of variation), recovery (49.6%–77.1%), matrix effect (46.7%–156.9%), and accuracy (81.2%–113.1% for PCBs, 85.8%–112.2% for PBDEs, and 55.2%–113.9% for OCPs). Its linearity was R2 > 0.99 for 84 compounds, and 96% average accuracy (for APCI) was obtained using the National Institute of Standards and Technology (NIST) standard reference materials (NIST 1957 and 1958). These ionization methods were compared by analyzing 25 real human serum samples. The observed species were 1.1–24.6 pg/mL of 28 PCBs, 2.5 pg/mL of BDE-47, and 6.5–195.1 pg/mL of 6 organochlorine pesticides (median concentration for each species), and only 11 compounds were detected with APCI owing to its enhanced sensitivity. © 2020 Elsevier B.V.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sang Beom photo

Han, Sang Beom
약학대학 (약학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE