Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Multiplexed Silicon Nanowire Tunnel FET-Based Biosensors with Optimized Multi-Sensing Currents

Authors
Kim, SihyunLee, RyoongbinKwon, DaewoongKim, Tae-HyeonPark, Tae JungChoi, Sung-JinMo, Hyun-SunKim, Dae HwanPark, Byung-Gook
Issue Date
Apr-2021
Publisher
Institute of Electrical and Electronics Engineers Inc.
Keywords
Biosensor with CMOS read-out circuit; Biosensors; GIDL-based FET biosensor; Gold; Logic gates; Multiplexed biosensor; Multiplexing; Sensors; Silicon; TFETs; Tunnel FET biosensor
Citation
IEEE Sensors Journal, v.21, no.7, pp 8839 - 8846
Pages
8
Journal Title
IEEE Sensors Journal
Volume
21
Number
7
Start Page
8839
End Page
8846
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/43986
DOI
10.1109/JSEN.2021.3054052
ISSN
1530-437X
1558-1748
Abstract
In this study, silicon nanowire (SiNW) FET-based and SiNW tunnel FET (TFET)-based biosensors are co-integrated with CMOS circuits by using top-down approached and CMOS-compatible back-end process simultaneously. The possibility of multiplexed sensing is verified with the fabricated FET and TFET biosensors. For multiplexed-sensing, two separate sensing materials which react with two distinct bio-targets are formed by partially capping the gold on SiO2 film through a lift-off process. Then two bio-receptors which selectively combine to the gold and the SiO2 are deposited. After the reaction of each biomolecule to each receptor, the changes of saturation and gate-induced-drain-leakage (GIDL) currents are monitored in the FET sensor. It is experimentally confirmed that two different biomolecules are independently detectable by the changes of the saturation and the GIDL currents in the FET sensor. To solve the dependence of the gold formation position on the sensitivity as well as the large current difference between the saturation and the GIDL currents, we demonstrated the TFET biosensor which uses the changes of tunneling and ambipolar currents generated in the source and the drain end. As a result, it is clearly revealed that two different biomolecules can be detected without interference, regardless of the position of the gold layer by the changes of the tunneling and the ambipolar currents with almost equivalent sensing current level. IEEE
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Natural Sciences > Department of Chemistry > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Tae Jung photo

Park, Tae Jung
자연과학대학 (화학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE