Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Nondisplaced fractures on hip CT: added value of dual-energy CT virtual non-calcium imaging for detection of bone marrow edema using visual and quantitative analyses

Authors
Jang, Seong WonChung, Bo MiKim, Wan TaeGil, Jea Ryung
Issue Date
Nov-2019
Publisher
SAGE PUBLICATIONS LTD
Keywords
Dual-energy computed tomography; CT; bone marrow edema; occult hip fracture; virtual non-calcium
Citation
ACTA RADIOLOGICA, v.60, no.11, pp 1465 - 1473
Pages
9
Journal Title
ACTA RADIOLOGICA
Volume
60
Number
11
Start Page
1465
End Page
1473
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/44573
DOI
10.1177/0284185119831690
ISSN
0284-1851
1600-0455
Abstract
Background Dual-energy computed tomography (DECT) virtual non-calcium (VNCa) imaging can demonstrate bone marrow edema. Purpose To evaluate the added value of DECT VNCa imaging for detection of non-displaced fractures on hip CT and to determine the attenuation value cut-off to identify bone marrow edema around fractures. Material and Methods We identified 35 patients who underwent DECT due to suspicion of a non-displaced fracture of the proximal femur or pelvic bone. Twenty-seven non-displaced fractures were present in 24 patients, while 11 patients had no fractures. Radiological, clinical follow-up, or surgical record was the standard of reference. Two radiologists visually interpreted CT images in two sessions: one with bone reconstruction images only and one with bone reconstruction images and VNCa images. Diagnostic performances were compared between the two reading sessions. Quantitative analyses of CT numbers on VNCa images were performed and a cut-off value was obtained through receiver operating characteristic (ROC) analysis. Results In the visual analysis, area under the curve, sensitivity, and negative predictive value were improved in the second session with VNCa images for both readers. In the quantitative analysis, a cut-off value of -55.3 HU yielded 100% sensitivity, 94% specificity, 95.4% accuracy, 69.0% positive predictive value, and 100% negative predictive value for detection of non-displaced fractures. Conclusion Visual and quantitative analyses of VNCa images may be useful in detection of non-displaced fractures in the proximal femur and in pelvic bones.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Bo Mi photo

Chung, Bo Mi
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE