Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

전국의료관련감염감시체계 중환자실 부문 결과 보고: 2016년 7월부터 2017년 6월Korean National Healthcare-associated Infections Surveillance System, Intensive Care Unit Module Report: Summary of Data from July 2016 through June 2017

Authors
곽이경최영화최준용유현미이상오김홍빈한수하이미숙김효열김성란김태형박선희유소연최평균은병욱신명진최지연구현숙어영유진홍
Issue Date
2018
Publisher
대한의료관련감염관리학회
Keywords
Healthcare-associated Infection; Intensive care unit; Korean National Healthcare-associated Infections Surveillance System; KONIS
Citation
의료관련감염관리, v.23, no.2, pp 25 - 38
Pages
14
Journal Title
의료관련감염관리
Volume
23
Number
2
Start Page
25
End Page
38
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/45416
ISSN
1226-2382
Abstract
배경: 전국의료관련감염감시체계(Korean National Healthcare-associated Infections Surveillance System, KONIS) 중환자실 부문에서 2016년 7월부터 2017년 6월까지 감시를 수행한 열 번째 연간 자료 보고이다. 방법: 전국에 있는 193개 병원의 285개 중환자실에서 발생한 의료관련 요로감염, 혈류감염, 폐렴에 대해 전향적으로 감시를 수행하였다. 의료관련감염률과 기구관련 의료관련감염률은 1,000 재원일수(patient-days, PD) 또는 1,000 기구일수(device-days, DD) 당 감염 건수로 구하였다. 기구사용비는 기구일수/재원일수로 계산하였다. 결과: 총 3,989건의 의료관련감염이 발생하였는데, 요로감염이 1,241건, 혈류감염이 1,757건, 폐렴이 991건이었다. 유치도뇨관 관련 요로감염은 1,189건으로 1.01/1,000 DD (95% 신뢰구간, 0.95-1.07)이었고, 유치도뇨관 사용비는 0.85 (95% 신뢰구간, 0.849-0.851)로 각각 전년도의 0.88/1,000 DD (95% 신뢰구간, 0.82-0.95)와 0.84 (95% 신뢰구간, 0.839-0.841)에 비해 높았다. 중심정맥관 관련 혈류감염은 1,481건으로 감염률은 2.23/1,000 DD (95% 신뢰구간, 2.12-2.35)이었고, 중심정맥관 사용비는 0.48 (95% 신뢰구간, 0.479-0.481)였다. 인공호흡기 관련 폐렴은 480건으로 감염률은 1.00/1,000 DD (95% 신뢰구간, 0.91-1.09)이었고, 인공호흡기 사용비는 0.35 (95% 신뢰구간, 0.349- 0.351)이었다. 결론: 전년도 자료와 비교할 때 전체 의료관련감염률은 유사하였으나 유치도뇨관 관련 요로감염 발생률이 증가하였다.
Background: In this report, we present the annual data of the intensive care unit (ICU) module of the Korean National Healthcare-associated Infections Surveillance System (KONIS) from July 2016 through June 2017. Methods: We performed a prospective surveillance of healthcare-associated urinary tract infection (UTI), bloodstream infection (BSI), and pneumonia (PNEU) at 285 ICUs in 193 hospitals using KONIS surveillance system. Healthcare-associated infection (HAI) and device-associated infection rates were calculated as the numbers of infections per 1,000 patient-days (PD) and device-days (DD), respectively. Device utilization was calculated as a ratio of device days to patient days. Results: A total of 3,989 HAIs were found during the study period; 1,241 UTIs (1,189 cases were urinary catheter-associated), 1,757 BSIs (1,481 were central line-associated), and 991 PNEUs (480 were ventilator-associated). The rate of urinary catheter-associated UTIs (CAUTI) was 1.01 cases per 1,000 DD (95% confidence interval [CI], 0.95–1.07) and urinary catheter utilization ratio was 0.85 (95% CI, 0.849–0.851). These were higher than the data of the previous year, 0.88/1,000 DD (95% CI, 0.82-0.95) and 0.84 (95% CI 0.839-0.841), respectively. The rate of central line-associated BSIs was 2.23/1,000 DD (95% CI, 2.12–2.35) while the central line utilization ratio was 0.48 (95% CI, 0.479–0.481). The rate of ventilator-associated PNEUs was 1.00/1,000 DD (95% CI, 0.91–1.09) while the ventilator utilization ratio was 0.35 (95% CI, 0.349–0.351). Conclusion: The overall HAI rate was similar to that of the previous year but the rate of CAUTI increased.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE