Use of ternary blended concrete to mitigate thermal cracking in massive concrete structures-A field feasibility and monitoring case study

Authors
Jung, Sang HwaChoi, Young CheolChoi, Seongcheol
Issue Date
Apr-2017
Publisher
ELSEVIER SCI LTD
Keywords
Mock-up test; Strain; Temperature; Ternary blended concrete; Thermal cracking
Citation
CONSTRUCTION AND BUILDING MATERIALS, v.137, pp 208 - 215
Pages
8
Journal Title
CONSTRUCTION AND BUILDING MATERIALS
Volume
137
Start Page
208
End Page
215
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/4569
DOI
10.1016/j.conbuildmat.2017.01.108
ISSN
0950-0618
1879-0526
Abstract
This study aimed to evaluate the field feasibility of a newly developed ternary blended concrete mix and its effect on mitigating thermal cracking in massive concrete structures. Four mock-up test members were cast using diffdrent types of cementitious binders, and variations in temperature and strain with time were monitored for these members. Results showed that reduced heat of hydration in the ternary mix significantly diminished variations in temperature and strain in the test member. A crack survey revealed that the ternary mix reduced the extent of thermal cracking and tightened crack widths, indicating that it can be used to effectively control thermal cracks in massive concrete structures. (C) 2017 Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Seong Cheol photo

Choi, Seong Cheol
공과대학 (건설환경플랜트공학)
Read more

Altmetrics

Total Views & Downloads

BROWSE