Prevalidation trial for a novel in vitro eye irritation test using the reconstructed human cornea-like epithelial model, MCTT HCE (TM)

Authors
Yang, HyeriKim, Da-eunJang, Won-HeeAn, SusunCho, Sun-AJung, Mi-SookLee, Ji EunYeo, Kyung-WookKoh, Sang BumJeong, Tae-CheonKang, Mi-JeongChun, Young-JinLee, Su-HyonLim, Kyung-MinBae, SeungJin
Issue Date
Mar-2017
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Eye irritation test; MCIT HCE (TM); Reproducibility; Predictive capacity; Statistical analysis
Citation
TOXICOLOGY IN VITRO, v.39, pp 58 - 67
Pages
10
Journal Title
TOXICOLOGY IN VITRO
Volume
39
Start Page
58
End Page
67
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/4705
DOI
10.1016/j.tiv.2016.11.010
ISSN
0887-2333
1879-3177
Abstract
Here, we report the results of a prevalidation trial for an in vitro eye irritation test (EIT) using the reconstructed human cornea-like epithelium, MCTT HCM (TM) The optimal cutoff to determine irritation in the prediction model was established at 35% with the receiver operation characteristics(ROC) curve for 126 substances. Within lab (WL) and between-lab(BL) reproducibility was tested for 20 reference substances by 3 participating laboratories. Viability data described by mean +/- SD or +/- 1/2 difference between duplicate wells, and scatter plots, demonstrated the WL/BL consistency. WL/BL concordance with the binary decision, whether non-irritant or irritant was estimated to be 85-95% and 95%, respectively. WL/BL reproducibility of viability data was further supported by a strong correlation(ICC, r> 0.9). WL/BL agreement of binary decisions was also examined by Fleiss' Kappa statistics, which showed a strong level of agreement (>0.78), nevertheless weaker than the reproducibility of the viability. The EIT with HCE (TM) exhibited a sensitivity of 82.2% (60/73), a specificity of 81.1% (43/53), and an accuracy of 81.8% (103/126) for 126 reference substances (for liquids; a sensitivity of 100% (47/47), a specificity of 70.6% (24/34), and an accuracy of 87.7% (71/81), and for solids, a sensitivity of 50% (13/26), a specificity of 100% (19/19), and an accuracy of 71.1% (32/45), suggesting that the accuracy is satisfactory but the sensitivity needs improvement, which shall be addressed through correcting the poor sensitivity for solid substances in future full validation trials. (C) 2016 Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Pharmacy > School of Pharmacy > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chun, Young Jin photo

Chun, Young Jin
약학대학 (약학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE