Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Fabrication of an electrochemical biosensor composed of multi-functional Ag ion intercalated DNA four-way junctions/rhodium nanoptate heterolayer on a micro-gap for C-reactive protein detection in human serum

Authors
Kim, JinmyeongPark, Jeong-AhYim, GyeonghyeJang, HongjeKim, Tae-HyungSohn, HiesangLee, Taek
Issue Date
7-Apr-2021
Publisher
ROYAL SOC CHEMISTRY
Citation
ANALYST, v.146, no.7, pp 2131 - 2137
Pages
7
Journal Title
ANALYST
Volume
146
Number
7
Start Page
2131
End Page
2137
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/47760
DOI
10.1039/d0an02135k
ISSN
0003-2654
1364-5528
Abstract
As inflammation plays a role in the pathogenesis of acute coronary syndromes, C-reactive protein (CRP) can be used as a biomarker. To detect CRP precisely, the authors prepared a CRP electrochemical biosensor consisting of an eight Ag ion-intercalated multifunctional DNA four-way junction (MF-DNA-4WJ) and a porous rhodium nanoparticle (pRhNP) heterolayer on a micro-gap electrode. To increase conductivity, we used eight Ag+ ion-inserted DNA four-way junctions through a C-C mismatch. Each DNA 4WJ was designed to have the CRP aptamer sequence, an anchoring region (thiol group), and two of four C-C mismatch regions at the end of the fragments. After an annealing step, the MF-DNA-4WJ assembly configuration and selective binding of CRP were confirmed through native TBM-PAGE (Tris-borate-magnesium chloride-polyacrylamide gel electrophoresis). The Au micro-gap electrode was fabricated to load 5 mu l of the sample, and this was performed during eight experiments on one chip to establish the accuracy of the data. Then, pRhNPs were immobilized on a Au micro-gap electrode using cysteamine. To confirm the electrochemical properties, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were conducted. The durability of pRhNPs was confirmed through CV. To test the sensing performance of the prepared CRP biosensor, the limit of detection (LOD) and selectivity tests were conducted using EIS. The results indicated that charge transfer resistance (R-ct) can be used efficiently to probe these interactions within the variable CRP concentration range, from 1 pM to 100 nM (0.23 ng L-1 -23 mu g L-1). The LOD of this sensor was 0.349 pM (0.08 ng L-1) (at S/N = 3). As a result of diluting the CRP to the same concentration range in a 20% human serum sample, the LOD was 3.55 fM (0.814 pg L-1) (at S/N = 3).
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of ICT Engineering > School of Integrative Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Tae-Hyung photo

Kim, Tae-Hyung
창의ICT공과대학 (융합공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE