Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Design and Validation of BAT Algorithm-Based Photovoltaic System Using Simplified High Gain Quasi Boost Inverteropen access

Authors
Rajalakshmi, ManiChandramohan, SankaralingamKannadasan, RajuAlsharif, Mohammed H.Kim, Mun-KyeomNebhen, Jamel
Issue Date
Feb-2021
Publisher
MDPI
Keywords
BAT algorithm; SHGqBI; photovoltaic; boost inverter; total harmonic distortions
Citation
ENERGIES, v.14, no.4
Journal Title
ENERGIES
Volume
14
Number
4
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/48134
DOI
10.3390/en14041086
ISSN
1996-1073
1996-1073
Abstract
Owing to the intermittent nature of renewable energy systems, an improved power extraction technique and modernized power modulators are to be designed to overcome power quality challenges. Attesting to this fact, this work aims to enhance the efficiency of the photovoltaic (PV) system using the BAT algorithm (BA) and enhances the overall performance of the system using modified inverter topology. Specifically, a new power electronic modulator, i.e., a simplified high gain quasi-boost inverter (SHGqBI), is implemented to eliminate the downsides of the conventional system. The proposed inverter reduces the additional components that can condense the volume of the design with reduced conduction and switching losses. The combination of BA-based PV rated 250 W and novel inverter configuration pick the global peak power with enhanced power quality. Notably, BA extracts the maximum power from the panel meritoriously with about 98.8% efficiency. This is because BA uses the global input parameters to track the maximum power of the PV panel, whereas other conventional maximum power point tracking (MPPT) techniques used limited parameters. Further, the current and voltage total harmonic distortion (THD) of the proposed inverter are recorded, which show a commendable range of 2.7% and 10.2%, respectively. In addition, the efficiency of the inverter is found to be 97%. Consequently, the overall system efficiency is calculated and found to be 97.9%, providing greater advantages over a conventional system. The system is mathematically modelled using MATLAB/Simulink and validated through an experimental setup with the laboratory prototype model.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Energy System Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Mun-Kyeom photo

Kim, Mun-Kyeom
공과대학 (에너지시스템 공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE