펄스 변압기 방식의 게이트회로를 사용한 펄스 모듈레이터의 게이트 신호 왜곡의 저감 방안에 대한 연구A Study on the Reduction of Gate Signal Distortion of a Pulsed Power Modulator Using Pulse Transformer Type Gate Circuit

Authors
송승호이승희류홍제
Issue Date
2021
Publisher
한국조명.전기설비학회
Keywords
EMI; Gate driver; High-voltage; Modular structure; Pulsed power modulator
Citation
조명.전기설비학회논문지, v.35, no.1, pp 23 - 27
Pages
5
Journal Title
조명.전기설비학회논문지
Volume
35
Number
1
Start Page
23
End Page
27
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/48544
ISSN
1229-4691
Abstract
This paper presents the study on a cable structure to minimize gate signal distortion in a high-voltage pulsed power modulator. The distortion according to the structure of the cable for transmitting the control signal to the pulse transformer type gate circuit was measured and compared. The structure of the signal cable was compared with the two structures in parallel and orthogonal to the discharge loop through which high potential and large current flows. The experiment was conducted under conditions of 15 kV, 40 A pulse output. As a result of measuring the current waveform of each structure, it was verified that the distortion was at least 5 times less than that of the parallel structure when configured in a form orthogonal to the discharge loop.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Energy System Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ryoo, Hong Je photo

Ryoo, Hong Je
공과대학 (에너지시스템 공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE