Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Fabrication of an Electrochemical Aptasensor Composed of Multifunctional DNA Three-Way Junction on Au Microgap Electrode for Interferon Gamma Detection in Human Serum

Authors
Noh, SeungwooKim, JinmyeongPark, ChulhwanMin, JunhongLee, Taek
Issue Date
Jun-2021
Publisher
MDPI
Keywords
aptasensor; biomarker; IFN-gamma detection; electrochemical biosensor
Citation
BIOMEDICINES, v.9, no.6
Journal Title
BIOMEDICINES
Volume
9
Number
6
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/49880
DOI
10.3390/biomedicines9060692
ISSN
2227-9059
2227-9059
Abstract
Interferon gamma (IFN-gamma) is an important cytokine with antiviral, antibacterial, and immunosuppressive properties. It has been used as a biomarker for the early detection of several diseases, including cancer, human immunodeficiency virus (HIV), tuberculosis, and paratuberculosis. In this study, we developed an electrochemical biosensor composed of multifunctional DNA 3WJ to detect IFN-gamma level with high sensitivity. Each multifunctional triple-stranded aptamer (MF-3WJ) was designed to have an IFN-gamma aptamer sequence, anchoring region (thiol group), and 4C-C (cytosine-cytosine) mismatch sequence (signal generation), which could introduce silver ions. To generate the electrochemical signal, four Ag+ ions were intercalated (3wj b-3wj c) in the 4C-C mismatch sequence. MF-3WJ was assembled through the annealing step, and the assembly of MF-3WJ was confirmed by 8% tris-boric-EDTA native polyacrylamide gel electrophoresis. The Au microgap electrode was manufactured to load sample volumes of 5 mu L. The reliability of electrochemical biosensor measurement was established by enabling the measurement of seven samples from one Au microgap electrode. MF-3WJ was immobilized on the Au microgap electrode. Then, cyclic voltammetry and electrochemical impedance spectroscopy were performed to confirm the electrochemical properties of MF-3WJ. To test the electrochemical biosensor's ability to detect IFN-gamma, the limit of detection (LOD) and selectivity tests were performed by square wave voltammetry. A linear region was observed in the concentration range of 1 pg/mL-10 ng/mL of IFN-gamma. The LOD of the fabricated electrochemical biosensor was 0.67 pg/mL. In addition, for the clinical test, the LOD test was carried out for IFN-gamma diluted in 10% human serum samples in the concentration range of 1 pg/mL-10 ng/mL, and the LOD was obtained at 0.42 pg/mL.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of ICT Engineering > School of Integrative Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Min, Junhong photo

Min, Junhong
창의ICT공과대학 (융합공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE