Simple and portable on-site system for nucleic acid-based detection of Clostridium difficile in stool samples using two columns containing microbeads and loop-mediated isothermal amplification

Authors
Baek, ChangyoonLi, Yun GuangYoo, Hyun JinCui, Wen YingKang, Jia TongSon, JuwonMin, Junhong
Issue Date
Jan-2022
Publisher
SPRINGER HEIDELBERG
Keywords
Clostridium difficile; Stool sample; Graphene oxide; Portable on-site system; Isothermal amplification
Citation
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, v.414, no.1, pp 613 - 621
Pages
9
Journal Title
ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume
414
Number
1
Start Page
613
End Page
621
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/50976
DOI
10.1007/s00216-021-03557-4
ISSN
1618-2642
1618-2650
Abstract
It is challenging to employ nucleic acid-based diagnostics for the in situ detection of Clostridium difficile from complex fecal samples because essential sample preparation and amplification procedures require various experimental resources. In this study, a simple and effective on-site nucleic acid-based detection system was used to detect C. difficile in stool samples. Two columns containing different microbeads, namely, glass and functionalized graphene oxide-coated microbeads, were designed to remove relatively large impurities by filtration and concentrate bacteria, including C. difficile, from stool samples by adsorption. The bacterial nucleic acids were effectively extracted using a small bead beater. The effectiveness of enzyme inhibitors remaining in the sample was efficiently reduced by the direct buffer developed in this study. This sample preparation kit consisting of two simple columns showed better performance in real-time polymerase chain reaction (PCR) and equivalent performance in loop-mediated isothermal amplification (LAMP) than other sample preparation kits, despite 90% simplification of the process. The amplification-ready samples were introduced into two microtubes containing LAMP pre-mixtures (one each for E. coli as an external positive control and C. difficile) by a simple sample loader, which was operated using a syringe. LAMP, which indicates amplification based on color change, was performed at 65 degrees C in a small water bath. The limit of detection (L.O.D) and analytical sensitivity/specificity of our simple and effective kit were compared with those of a commercial kit. C. difficile in stool samples could be detected within 1 h with 10(3) cfu/10 mg using LAMP combined simple on-site detection kit.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of ICT Engineering > School of Integrative Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Min, Junhong photo

Min, Junhong
창의ICT공과대학 (융합공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE