Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Design of Compact Solid-State Modulator for High-Power Electromagnetic Pulse Generation

Authors
Cho, Chan-GiRyoo, Hong-Je
Issue Date
Oct-2021
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Capacitors; Switches; Batteries; Thyristors; Polymers; Lithium; Discharges (electric); DC-DC power converters; electromagnetic propagation; pulsed power supply; resonant converter(s); three phase
Citation
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, v.9, no.5, pp 6059 - 6068
Pages
10
Journal Title
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS
Volume
9
Number
5
Start Page
6059
End Page
6068
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/51346
DOI
10.1109/JESTPE.2021.3079330
ISSN
2168-6777
2168-6785
Abstract
The proposed compact solid-state modulator for the generation of high-power electromagnetic (HPEM) pulses uses a lithium polymer battery as the input power source and is capable of achieving a 100-Hz pulse discharge rate with a peak voltage of 400 kV for 2 min. The developed pulse generator consists of two charging units. The primary charging unit is designed to work with 200-A battery current, which increases switching losses and temperature increments at the main switch. To compensate the problems, a half-bridge three-phase structure is connected to transformers via the proposed delta-star connection that decreases the turns ratio of the three-phase transformer effectively. Furthermore, the resonant components are intentionally placed on the secondary side of the three-phase transformer, which is characterized by low current and high voltage conditions. The secondary charging unit uses the resonance between the two capacitors, and the inductor must protect not only the controller, which is susceptible to HPEM pulse effects, but also the output rectifying diodes of the primary charging unit from the peak 20-kA pulse discharging effect. The design procedures and analysis are verified with simulations for each charging unit. The experimental results using various loads, including the actual tesla transformer, validate the system performance and confirm a 94% power efficiency with a peak power density of 431 W/L.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Energy System Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ryoo, Hong Je photo

Ryoo, Hong Je
공과대학 (에너지시스템 공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE